Genie UKP-EM User Manual

Ip67 125khz universal multi-function keypad and proximity reader

Advertisement

Quick Links

IP67 125KHz Universal
Multi-Function Keypad and
Proximity Reader
UKP-EM
User Manual
Please read these instructions carefully before operating the unit
and keep for further reference.

Advertisement

Table of Contents
loading

Summary of Contents for Genie UKP-EM

  • Page 1 IP67 125KHz Universal Multi-Function Keypad and Proximity Reader UKP-EM User Manual Please read these instructions carefully before operating the unit and keep for further reference.
  • Page 2: Packing List

    2. Description The UKP-EM is a dual-relay access control keypad with EM & HID 125 KHz built in card reader. It is suitable for mounting either indoor, or outdoor in harsh environments. It 's housed in a strong, sturdy and vandal resistant, zinc alloy, electroplated case. The electronics are fully potted so the UKP-EM is waterproof and conforms to IP67.
  • Page 3: Installation

    4. Specification Operating Voltage DC12-24V Or AC12-18V User Capacity 2100 & 10 Additional groups for duress- PIN/Card Keypad 12 Keys, 3 x 4 Digits Card Type EM & HID 125 KHz Cards / Fobs RF Card Reading Distance 3 - 6 Cm Active Current Draw ≥...
  • Page 4: Wiring Guide

    6. Wiring Guide COLOUR FUNCTION DESCRIPTION Orange NC 1 RELAY 1 - NORMALLY CLOSED Purple RELAY 1 COMMON COM 1 Blue NO 1 RELAY 1 NORMALLY OPEN Green & Black RELAY 2 - NORMALLY CLOSED NC 2 Black & White COM 2 RELAY 2 COMMON Pink...
  • Page 5: Anti Tamper Alarm

    8. Anti Tamper Alarm The UKP-EM uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover, the tamper alarm will operate. 9. Sound & LED Indication...
  • Page 6 10.1 USER SETTINGS BUZZER GREEN AMBER SETTING STEPS STATUS LED STATUS LED STATUS LED STATUS OBSERVE KEYPAD STATUS BEFORE YOU START FLASHING OUT THE BOX TO ENTER PROGRAMMING MODE PRESS 1 BEEP ENTER 888 888 (DEFAULT MASTER CODE) 6 BEEPS PRESS SHORT FLASH 1 BEEP...
  • Page 7 10.4 SETTING OPERATIONAL MODES BUZZER GREEN AMBER SETTING STEPS STATUS LED STATUS LED STATUS LED STATUS ENTER PROGRAMMING MODE SETTING OPERATIONAL MODE 1 BEEP / KEY USING MASTER CODE ON AFTER SHORT FLASH ON AFTER CARD OR PIN MODE (DEFAULT SETTING) PRESS FOR RELAY 1 1 BEEP / KEY...
  • Page 8 BUZZER GREEN AMBER SETTING STEPS STATUS LED STATUS LED STATUS LED STATUS ENTER PROGRAMMING MODE TO DELETE A PIN NUMBER SHORT FLASH 1 BEEP USING MASTER CODE USER ID LOCATION SHORT FLASH 1 BEEP / KEY PRESS 1 BEEP / KEY PRESS AGAIN TO EXIT FLASHING...
  • Page 9 METHOD 3 - MANUAL ID ALLOCATION BUZZER GREEN AMBER SETTING STEPS STATUS LED STATUS LED STATUS LED STATUS ENTER PROGRAMMING MODE ADDING CARDS VIA MANUAL ID INPUT SHORT FLASH 1 BEEP USING MASTER CODE FOR RLY 1 1 BEEP / KEY USER ID (1-2000) USER ID (2001-2100) FOR RLY 2...
  • Page 10 10.8 ALLOCATING A PIN NUMBER TO A CARD USER (FOR CARD AND PIN USE) ALLOCATING PIN NUMBER TO CARD BUZZER GREEN AMBER SETTING STEPS STATUS LED STATUS LED STATUS LED STATUS ENTER PROGRAMMING MODE ADDING CARDS VIA BLOCK ENROLMENT SHORT FLASH 1 BEEP USING MASTER CODE SET CARD AND PIN MODE AS PER SEC...
  • Page 11: Relay Settings

    11. Door Operation - (Gaining Access) FOR PIN USER ENTER PIN NO. FOLLOWED BY FOR CARD USER JUST READ THE CARD FOR CARD AND PIN USER READ CARD, FOLLOWED BY PIN AND 11.1 Relay Settings (Pulse Mode / Toggle Mode) SETTING PULSE MODE (DEFAULT) BUZZER GREEN...
  • Page 12 *PLEASE NOTE, IMPORTANT* **THE FOLLOWING FUNCTIONS ARE ALL PERFORMED IN PROGRAMMING MODE** 12. 1 DOOR SENSORS DETECTION - SETTING TO DISABLE DOOR OPEN DETECTION (DEFAULT) TO DISABLE DOOR OPEN DETECTION (DEFAULT) TO EXIT PROGRAMMING PRESS TO EXIT 12. 2 KEYPAD LOCKOUT & ALARM OUTPUTS - SETTING Keypad Lockout &...
  • Page 13 TO EXIT PROGRAMMING PRESS TO EXIT 12. 5 KEYPAD TONE - SETTING Keypad Tone: The keypad tone can be set On or Off. When on, the device will BEEP when a Key is pressed and when off, the device will be silent. KEYPAD TONE SETTING DISABLE TONE ENABLE TONE (DEFAULT)
  • Page 14 TO EXIT 14.0 WIEGAND MODE - SETTING UKP-EM Supports Wiegand 26 ~ 37 Bit Input and Output. The Unit May Be Used As just as an Output reader or a Controller. 26 ~ 37 TO ADD A DURESS PIN USER...
  • Page 15: Interconnecting Two Devices

    15.1 OPERATING AS A WIEGAND OUTPUT READER In This Mode, The UKP-EM Supports Wiegand 26 ~ 37 Bit Output. Therefore, D1 & D0 Wiegand Data Lines Can be Connected to Any Control Panel That Supports Wiegand 26 or 37. IT'S IMPORTANT THAT IN THIS CASE THE KEYPAD SHARES THE 3RD PARTY CONTROLLER'S PSU GROUND...
  • Page 16 15.2 UKP-EM OPERATING AS A CONTROLLER In this mode the UKP-EM supports a Wiegand 26~37 bit input so an external Wiegand device with a 26~37 bit output can be connected to the Wiegand input terminals on the UKP-EM. Either an ID card reader (125 KHz) or an IC card reader (13.56MHz) can be connected to the UKP-EM.