Alignment Tape
ST-N5
ST-NF
VTR cleaning kit
JG022 Master Plane
Tentelometer
Ref. No.
Part No.
JG002B
APJG002B00
Adapter
JG002E
APJG002E00
Dial Torque Gauge (10~90gf•cm)
JG002F
APJG002F00
Dial Torque Gauge (60~600gf•cm)
JG022
APJG022000
Master Plane
JG024A
APJG024A00
Reel Disk Height Adjustment Jig
JG153
APJG153000
X Value Adjustment Screwdriver
JG154
APJG154000
Cable
How to use the Servicing Fixture
1.
Remove the Syscon PCB from the set.
Be sure to place the parts on a paper so that they have no short-circuit each other.
2.
Short circuit between TP1001 and Ground with the cable JG154.
(The BOT, EOT, and the Reel Sensor do not work and the deck can be operated without a cassette tape.)
3.
In case of using a cassette tape, press the STOP/EJECT button to insert or eject a cassette tape.
Turn on the power and re-check the cable before checking the trouble points.
All manuals and user guides at all-guides.com
SERVICING FIXTURES AND TOOLS
Back tension cassette gauge
70909103
VTR lubrication kit
JG024A Reel Disk Height
Adjustment Jig
Parts Name
PREPARATION FOR SERVICING
D1-1
Torque cassette gauge
(KT-300NR)
70909199
Grease
JG153 X Value Adjustment
Screwdriver
Remarks
VSR Torque, Brake Torque (S Reel/T Reel Ass'y)
Brake Torque (T Reel Ass'y)
VSR Torque, Brake Torque (S Reel)
Reel Disk Height Adjustment
Reel Disk Height Adjustment
X Value Adjustment
Used to connect the test point of SERVICE and GROUND
Taper nut driver
70909228
JG002B
Adapter
JG002E
Dial Torque Gauge
(10~90gf•cm)
JG002F
(60~600gf•cm)
JG154 Cable