Item
Adjustment
Data
number Item
range
3A
DKS
00–01
3B
MUT
00–01
3C
ABL
00–01
3D
SCM
00–01
3E
FBT
00–01
3F
OP0
00–FF
40
OP1
00–FF
41
OP2
00–FF
NOTE
•
Standard Data: Those are the standard data values written on the microprocessor. Therefore, the data values of the
modes are stored respectively in the memory.
In case of a device replacement, adjustment by rewriting the data value is necessary for some items.
•
50 ...................... 50 Hz data
•
60 ...................... 60 Hz data
•
Standard data listed on the adjustment item table are reference values, therefore it is different for every model.
All manuals and user guides at all-guides.com
Initial
Standard data
data
01
00
00
00
01
2F
0F
00
– 23 –
KV-J14P2S/J51PF2S
Note
D/K Stereo enable/disable
Muting on/off at No. Sync
Bright ABL Switch
SECAM Trap active/inactive
FBT L/S C/M strict/plain
Optional Flags 0 (see below) Other Control
Optional Flags 1 (see below) Other Control
Optional Flags 2 (see below) Other Control
RM-869
Device
Other Control
Other Control
Other Control
Other Control
Other Control