Summary of Contents for nama GF-12HC-N

  • Page 1       ___________ SERIAL NO. 한 한 글 글 및 및 영 영 문 문 안 안 내 내 서 서                   1     ...
  • Page 2: Installation

      INSTRUCTION MANUAL   REFLOW SOLDER MACHINE   MODEL GF‐12HC‐HT‐N WARNING: FAILURE TO READ AND FOLLOW THESE INSTRUCTIONS IN THEIR ENTIRETY PRIOR TO INSTALLATION AND OPERATION MAY VOID WARRANTY AND RESULT IN PERSONAL INJURY AND DAMAGE TO PROPERTY! Please pay particular attention to all items marked “CAUTION!” in manual. Be sure that all personnel who are to operate this machine are first fully familiar with this manual and are instructed on proper safety procedures, practices and precautions.
  • Page 3: Specifications

    D. Utilizing the jacking screws, carefully level and machine at its permanent location. Please check that the hood opens and closes properly, and re-evel as necessary. E. Attach 4” diameter (155mm) metal duct to the header flange located on top of the machine. Provide suction to draw approximately 100 cubic feet per minute maximum (2832 liters per min max.).
  • Page 4 IMPORTANT! Check all connections and carefully inspect entire machine and installation prior to start-up. *중요사항  기기를 가동시키기에 앞서, 모든 연결부위를 세밀히 체크하고, 기기 전체와 설치 상태를 다시 한번 검사합니다  III. OPERATION A. Turn all switches to OFF position. B. Make sure entire conveyor path is clear and close hood. Turn MAIN POWER switch on. An EMERGENCY STOP switch (E-Stop) is located at the right front of the oven which, when activated, immediately shuts power to the conveyor and all heat controllers.
  • Page 5 원상복구 시킵니다. D.  기기를 작동하실 때는, 다음 장의 Process Sentry computer controller 에 기술된 절차를 따릅니다.    *주의사항 사고를 방지하기 위하여, 손가락, 머리카락, 헐렁하게 처지는 옷, 보석 및 다른 물건들을 컨베이어 끝 쪽에 닿지 않게 하십시오. 후드는 항상 열릴 수 있지만 안전 스위치가 가열 시스템을 차단합니다. *주의사항 기기가 뜨거울 때 후드가 열리면, 모든 내부와 주위 표면에 닿지 않도록 주의하십시오. (컨베이어...
  • Page 6 Exhaust Flange Cooling Station Emergency Stop Conveyor extension DB-25 Connector Main Power Switch   Profile Port   그림 1...
  • Page 7: Machine Start-Up

    IV. OVEN OPERATION USING COMPUTER CONTROLLED PROCESS SENTRY The APS ProcessSentry is a microprocessor based, dedicated computer used for controlling and operating all parameters of the GF-12HC oven. The computer operates in one of 6 modes. ProcessSentry includes a 7 day timer, 100 menu storage, English or metric units, RS 232 interfaceable, SPC fault monitoring and graphic profiling.
  • Page 8 보기(view) 작동(work) 셋업(setup) 프로파일(profile) 로그(log) 튜닝(tune) F3를 다시 누르면 이 모드에서 나갈 수 있습니다. B. VIEW Mode: Operator can observe menu numbers 0-100. When switching to WORK mode, parameters seen in VIEW mode will be displayed for use. . 보기(VIEW)모드: 작동자가 0~100 까지의 숫자를 볼 수 있습니다. 작동(work)모드로...
  • Page 9 g. Auxiliary external output: a DC output signal is provided on the main control board at pin #8. This signal may be used to power a solid state relay which can turn on or off any external device such as a computer, a printer, exhaust fans, input or output conveyors etc. To toggle the signal on, press the left and right arrows (◄►) simultaneously.
  • Page 10 a. Press Security Code F2-◄-▲-▼and hold simultaneously until table appears b. Scroll to appropriate field using left and right arrows (◄►) c. Scroll up, scroll down arrows (▲▼) change setting of each parameter: i. MENU 1. FULL option: allows access to all modes 2.
  • Page 11 그림3 viii. CYCS - Shows number of cyclonic generators in machine ix. COOL - Jacket and/or control panel cooling fans stay on for indicated time of up to 60 minutes (in 10 minute increments) after shutdown. x. CONVEYOR - DO NOT CHANGE (factory set) xi.
  • Page 12 E. RAMP T OUT- 제조사에서 설정한 것을 변환하지 마십시오. F. 스케쥴(Schedule)- 엔터키를 눌러 7일 타이머를 작동시켜, 시작과 끝나는 시간 및 매일매일의 프로파일러 값을 설정합니다. OFF로 설정된 날은 자동 타이머가 실행되지 않습니다. 셋업 모드로 다시 나가려면 F3키를 누르십시오. G. 프로브(Prob)- 프로파일링에 이용되는 외장 열전지의 저항 값을 측정합니다. 10의 자리에서 반올림 한 후...
  • Page 13 PROF-(그림3) 그래픽 프로파일을 변환시키기 위해 다음의 항목을 셋팅합니다. Time in minute.( 4 또는 8분으로 설정)  Maximum Temp ( 최대 온도값 설정으로, 260℃ 또는 371℃로 설정합니다)  Temp 1 ( 임시로 표시되는 가로선은 온도 실행을 위한 셋팅입니다.)  4.   CYC‐ 사이클론식 발전기 셋팅을 20%에서 100% 범위에서 조절 할 수 있으며 정지 후 10% 정도의 잔여  작동시간이 있습니다.  발전기를 끄기 위해서는 0%로 셋팅합니다.  5.  COOL‐ 쿨링 스테이션 셋팅을 20% 에서 100% 범위에서 조절 할 수 있으며, 정지시킨 후 10%의 잔여 ...
  • Page 14 ENHANCED PRINTING OPTION: A serial printer or PC may be connected to the DB-25 connector located on the left end of the control panel near the fan grille. With a PC, launch Microsoft Hyperterminal and set up the parameters below. With a serial printer set parame- ters, below: BAUD: 4800 bps DATA BITS: STOP BITS:...
  • Page 15 이벤트 로그를 출력하려면 LOG모드에서 F2를 누릅니다. *주의사항: 기기 Work모드나 Tune모드에서 로그 이벤트가 발생할 때마다 자동으로 프린트됩니다. SPC데이터를 수집하기 위해서는, Work모드에서 F2키와 좌 (◀), 상(▲) 화살표 키를 동시에 눌러 현재의 모든 파라미터를 즉시 출력할 수 있습니다. 프로파일 그래프를 출력하기 위해서는, Work 모드에서 F1키를 눌러 그래프 스크린 상태로 들어갑니다. 프로파일이 실시간으로...
  • Page 16 시간이 현재 시간 위에 보여집니다. CAUTION! DO NOT TURN MAIN POWER SWITCH OFF, AS THIS WILL DEFEAT THE CHAMBER COOLING FAN TIMER, and thus prevent the machine from cooling itself sufficiently prior to full shutdown. After the chamber cooling fan timer has expired, the main MAIN POWER switch may be turned off, providing automatic timer is not being utilized.
  • Page 17 E. Apply a light coat of high temperature furnace lubricant (non-silicone based), to the upper surfaces of the brass conveyor support guides as necessary. Conveyor squeaking or scratching sounds indicate an absence of sufficient lubrication. F. Bearings used in your machine are pre-lubricated and sealed, thus requiring no regular maintenance.
  • Page 18 LCD Menu Reflow 조건 화면 3 Zone Reflow 구간 / Fan 속도 / Cooling...
  • Page 19 Key 선택 Function Main 화면...
  • Page 20 Key Function...