2. POWER AMPLIFIER ADJUSTMENT

Idling Current Alignment
1. Each of the measurement points are provided with the
two test points. Set a digital Voltage meter to DC voltage
input, connect the meter to the test points at both contact
points.
2. After the setup above, turn on the main switch.
3. Adjust variable resistors (VR20 - VR50) according to the
digital voltmeter readings. The target setting value is the
following table for each channel.
Settings : No-signal of input
Speaker out
— No Load
Top lid
— OPEN
Measurement Point
AMP PWB
Front side
AMP PWB
Rear side
AMP PWB
Time Table of Idling Current Rise
(CHANNEL 1)
FAN
(CHANNEL 3)
Channel
SL (CHANNEL 3)
SR (CHANNEL 4)
SBL (CHANNEL 5)
SBR (CHANNEL 6)
L (CHANNEL 1)
R (CHANNEL 2)
C (CHANNEL 7)
OPT (CHANNEL 8)
After Turning ON
10 min.
20 min.
30 min.
L
R
(CHANNEL 2)
VR50
VR40
CN50
CN40
POWER AMP MODULE
MAIN HEAT SINK
SL
SR
(CHANNEL 4)
VR20
VR30
CN20
CN30
2. POWER AMPLIFIER ADJUSTMENT
アイドリング電流調整
電源を
する前にそれぞれの
1.
ON
ルボルトメーターを接続します。デジタルボルトメーター
電圧入力にセットします。
DC
上記のセットアップの後に、本機の電源を
2.
デジタルボルトメーターの電圧値を監視しながら可変抵抗
3.
(VR20
VR50)
各チャンネルの目標値は下記の表を参照下さい。
セッティング
入力信号無し
:
スピーカー接続 ̶ 無し
トップカバー
フロント側のパワーアンプ
4 (SR) CHANNEL 5 (SBL)/ CHANNEL 6 (SBR)
リング電流調整を行う場合はフロントパネルを外して行っ
てください。
Adjustment
VR
VR20
VR30
VR40
VR50
VR50
VR40
VR30
VR20
Ambient temperature
20 to 30 degrees centigrade
Measurement Voltage
1.5 mV ± 0.2 mV
1.5 mV ± 0.2 mV
1.5 mV ± 0.2 mV
C
(CHANNEL 7)
VR30
CN30
REAR SIDE
FRONT SIDE
SBL
(CHANNEL 5)
VR40
CN40
2
端子と
端子間にデジタ
"+"
"-"
ON
を調節します。
無し
––
CHANNEL 3 (SL) / CHANNEL
Measurement Point
CN20
CN30
CN40
CN50
CN50
CN40
CN30
CN20
OPT
(CHANNEL 8)
VR20
CN20
SBR
(CHANNEL 6)
VR50
CN50
します。