Haier HW-DS50TVE Series Owner's Manual page 21

Front load washing machine
Table of Contents

Advertisement

Front Load Washing Machine
Check the import voltage between M1 wind
and M2 wind, is it between AC 220-240V?
Error message. Motor overheat protection or is damaged.
Troubleshooting:
Cut off power and check if motor wires
are connected well
Y
Measure if resistance of motor winding by
multimeter,is it as followed? 4-5:5Ω
5-6:5Ω
4-6:5Ω
Y
Pull out the wire connection of motor and
computer board.Then check if circuit is open
by multimeter
N
Turn on power and set spin mode,then
start.Check the import voltage of driving
board between red wire and red wires,
is it between 220-240V?
N
N
Repair wires
Y
Y
Model:HW-DS50TVE SERIES
Replace computer board
Reconnect well
Put the motor in nomal temperature about
ten minutes,and then test again.If the
N
resistance is natural,
it is caused by
overheated protection.Then check
deal with overload,abnormal voltage.If
not,please replace motor
Replace computer
board
and
18

Hide quick links:

Advertisement

Table of Contents
loading