7 Technical Specifi cations
Input Voltage:
230V ~ 50Hz.
Load:
400W class C halogen light plus additional loads,
three 400W class C halogen lights or fl uorescent loads
up to 200W can be connected.
Power Consumption: Less than 1W. (Quiescent)
Detection Angle:
10º ~ 240º adjustable for the outer zone detecting range
from 3 to 16m.
360º for the inner zone detection range within a radius of
approx. 3m.
Light ON Time:
Adjustable from about 6 seconds to 12 minutes.
METER
(range restriction): Adjustable 3 ~ 16m.
13
LUX:
Adjustable "ambient light level" control.
Adjustable Angle
Sensor Head:
Left or right 60º.
Floodlight:
Left or right 45º.
Up 50º and down 35º.
Environmental
Protection:
IP44.
Operating
Temperature:
-25ºC ~ +45ºC.
Temperature
Compensation:
On a very cold or hot day, the MLB/WPRO500C can
automatically adjust "detecting sensitivity" to reduce
the change of detection distance caused by the
ambient temperature change.
5 Year Guarantee
In the unlikely event of this product becoming faulty due to
defective material or manufacture within 5 years of the date of purchase,
please return it to your supplier in the first year with proof of purchase and
it will be replaced free of charge. For years 2 to 5 or any difficulty in the
first year telephone the helpline on
020 8450 0515.