Applies to control board 10013404
The target group for this installation manual is trained
qualified personnel entrusted with the technical
functioning and operation of the unit.
Read the installation instructions for the
units and observe the safety information.
Safety instructions
Organizational measures
Risk of property damage and personal injury from
lack of organizational measures
Use equipment and protective gear suitable for the
activity.
Danger of electric shock from live components.
Prior to working on the electrical system, switch off
the unit, disconnect the electrical system from the
mains and prevent power from being switched on
again. Check to ensure the system is dead.
Use only insulated tools.
Check before replacing
Troubleshoot using the service manual.
Order of steps
Only for units with Touch control panel: Back up
data if the Service menu can be accessed
Only for unit with Touch control panel: Export your
own cooking programs to a USB stick
Removing the operating panel
Only for units with Touch control panel: Reuse SD
card on the new control panel
Attaching the film keypad
Software update
Only for units with Touch control panel: Restore
the data
Only for units with Touch control panel: Load the
OEM settings and select the cookbook (option)
www.hennypenny.com
Control pcb replacement instructions (Combisteamer)
Unit with Touch control panel
Preparing the USB stick
Prerequisite
USB stick.
Maximum size 32 GB.
FAT formatting (default).
The disk should be empty if possible.
Current software update and additional content
The update is available at the manufacturer's
website.
INFORMATION
The additional content contains sound files and
graphics. They must be installed after the operating
panel has been replaced.
Preparing the USB stick
Open and unzip the file "help_additional_mp.zip".
In general, the unzipped folder is in the same
directory as the previously compressed one.
Copy the unzipped folders "MMIUpdate",
"MMIContent" and "FCImport" from the USB stick
to the root directory. The contents and folder
structure must not be changed.
Opening the Settings menu and Service menu
Replacement requires access to the settings menu,
basic settings.
Calling up the Setting menu
Switch on the unit.
Tap the "Unit functions" button.
Display of Appliance functions menu.
Tap the "Settings" field.
Display of PIN window.
Enter password "111" and tap the Confirm field.
Display of Device Settings menu.
Assembly instructions
1

Advertisement

loading

Summary of Contents for Henny Penny 10013404

  • Page 1 Control pcb replacement instructions (Combisteamer) Applies to control board 10013404 Unit with Touch control panel The target group for this installation manual is trained Preparing the USB stick qualified personnel entrusted with the technical functioning and operation of the unit.
  • Page 2: Opening The Appliance

    Control pcb replacement instructions (Combisteamer) Opening the Service menu Open and download Zip file and unzip. In general, the unzipped files are in the same directory as the Switch on the unit. previously compressed folder. Tap the "Unit functions" button. Copy both update files directly on the USB stick.
  • Page 3 Control pcb replacement instructions (Combisteamer) Overview Removing the control board Disconnect all connectors from the control board. Label sensor lines and communication lines if necessary. Remove grounding screw and strain relief. Remove the control board by unlocking the plastic clips. Detach the digital key.
  • Page 4 Control pcb replacement instructions (Combisteamer) Tap the "OK" field The software restarts automatically INFORMATION After the update, a blue screen may appear and the software does not start. In this case, switch the unit off and then back on. In rare cases, this may happen again.
  • Page 5 Control pcb replacement instructions (Combisteamer) Unit with Classic control panel USb SFL Open the Settings menu or Service menu. The password for the Settings menu is 111. Select Software Update using the left rotary knob "SFL". Image: USB stick or software update not detected Press the "START STOP"...