Applies to control board 10013404
The target group for this installation manual is trained
qualified personnel entrusted with the technical
functioning and operation of the unit.
Read the installation instructions for the
units and observe the safety information.
Safety instructions
Organizational measures
Risk of property damage and personal injury from
lack of organizational measures
•
Use equipment and protective gear suitable for the
activity.
Danger of electric shock from live components.
•
Prior to working on the electrical system, switch off
the unit, disconnect the electrical system from the
mains and prevent power from being switched on
again. Check to ensure the system is dead.
•
Use only insulated tools.
Check before replacing
Troubleshoot using the service manual.
Order of steps
•
Only for units with Touch control panel: Back up
data if the Service menu can be accessed
•
Only for unit with Touch control panel: Export your
own cooking programs to a USB stick
•
Removing the operating panel
•
Only for units with Touch control panel: Reuse SD
card on the new control panel
•
Attaching the film keypad
•
Software update
•
Only for units with Touch control panel: Restore
the data
•
Only for units with Touch control panel: Load the
OEM settings and select the cookbook (option)
www.hennypenny.com
Control pcb replacement instructions (Combisteamer)
Unit with Touch control panel
Preparing the USB stick
Prerequisite
USB stick.
Maximum size 32 GB.
FAT formatting (default).
The disk should be empty if possible.
Current software update and additional content
The update is available at the manufacturer's
website.
INFORMATION
The additional content contains sound files and
graphics. They must be installed after the operating
panel has been replaced.
Preparing the USB stick
Open and unzip the file "help_additional_mp.zip".
In general, the unzipped folder is in the same
directory as the previously compressed one.
Copy the unzipped folders "MMIUpdate",
"MMIContent" and "FCImport" from the USB stick
to the root directory. The contents and folder
structure must not be changed.
Opening the Settings menu and Service menu
Replacement requires access to the settings menu,
basic settings.
Calling up the Setting menu
Switch on the unit.
Tap the "Unit functions" button.
Display of Appliance functions menu.
Tap the "Settings" field.
Display of PIN window.
Enter password "111" and tap the Confirm field.
Display of Device Settings menu.
Assembly instructions