  • Page 1 HYDRO Handheld Touch Radio Hydro...
  • Page 3: Preface

    Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove. For further information and requirements contact your Ravelli-authorised Technical Assistance Centre. All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means, including photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buyer’s staff,...
  • Page 4: Table Of Contents

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.4 Sommario Preface..................................3 WARRANTY ..........................6 Certificate of warranty............................... 6 Warranty conditions ..............................6 Registration of warranty ............................6 Info and problems ..............................6 GENERAL INFORMATION ......................7 Supply and safe-keeping ............................7 Language ...................................
  • Page 5 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.5 OPERATING PHASES OF THE APPLIANCE ................34 Sequence of ignition phases ..........................34 Eco stop ................................... 34 Stand-by ................................... 34 Sanitary ..................................34 Description of menu functions ..........................34 Setting ..................................38 Anti-condensation system ............................
  • Page 6: Warranty

    Use and maintenance manual Touch Radio Hydro Pag.6 WARRANTY Certificate of warranty Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to: • read the installation, use and maintenance instructions for the product; •...
  • Page 7: General Information

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.7 GENERAL INFORMATION Supply and safe-keeping The manual is supplied in printed format. Keep this manual safe, with the stove, so that the user can consult it easily. The manual is an integral part, for safety reasons, therefore: •...
  • Page 8: Residual Risks

    If the chimney catches fire you must call the fire brigade. ⚠ Only use original spare parts. Any tampering and/or replacements that have not been authorised by Ravelli can pose a danger to the user’s safety. ⚠ In the event of particularly adverse weather conditions, the safety systems could intervene and switch off the stove.
  • Page 9: Description Of The Stove

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.9 residual description procedure-related information risk Risk of When the stove is running, it may reach high burns temperatures to the touch, especially on its external surfaces. Take care to avoid burns and use the specific tools if necessary.
  • Page 10: Obligations And Forbidden Actions

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.10 Obligations and forbidden actions Obligations The user must: • read this instructions manual before performing any operation on the stove; • the appliance must not be used by children under the age of 8 or...
  • Page 11: Characteristics Of The Fuel

    A2 and B. Maintain fuels and other flammables at a suitable distance. Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225-2:2014 standard, or certified DIN PLUS (more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show the name of the producer, the main characteristics and classification according to standards.
  • Page 12: Automatic Cleaning System

    User training Once installation is complete, the user must always be fully trained in the functions and characteristics of the stove by the technician authorized by Ravelli to ensure optimal and safe use. The training should cover the following topics: •...
  • Page 13: Safety Devices

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.13 Safety devices The stove has been designed and equipped with safety systems to minimize user risks. It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board.
  • Page 14: Shipping And Installation

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.14 SHIPPING AND INSTALLATION Safety warnings for transportation and installation �� The stove must be installed by a qualified technician, who must issue a declaration of conformity of the system to the purchaser, taking full responsibility for stove installation and correct operation.
  • Page 15: Set-Ups For The Smoke Evacuation System

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.15 Set-ups for the smoke evacuation system �� Be careful when building the smoke evacuation system and observe the regulations in force in the country where the stove ⚠ is installed.
  • Page 16: Installation

    �� Ravelli shall not be held liable if these precautions are not followed. Requirements for the installation premises The stove installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake connected to the outdoors.
  • Page 17 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.17 Installation example for a stove/pellet stove This type of installation (See Fig.1) requires an insulated chimney pot, even if the entire conduit is installed inside the building. Besides, the structure must be inserted into a properly ventilated skylight shaft.
  • Page 18 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.18 This type of installation (See Fig.4) requires an insulated chimney pot, even if the entire smoke conduit is installed outside the Protection from rain building. In the lower part of the chimney there is a "T" type fitting installed with inspection cap.
  • Page 19: Connections

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.19 CONNECTIONS �� The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer. �� By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75 ⚠...
  • Page 20: Connection Of External Probe Or Thermostat

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.20 Electrical connection The plug of the stove’s power cable must only be connected after the installation and assembly has been completed of the appliance, and must remain accessible after installation.
  • Page 21: Electric Scheme

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.21 Electric scheme LEGEND Safeties Probes T1- Pellet safety S- Flue gas probe (J) T2- Pressure switch S1- Probe H2O return / Probe Buffer L T3- Safeties door and/or ash S2- Flame probe (K)
  • Page 22: Connections For Hydraulic Diagrams

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.22 Connections for hydraulic diagrams Connections for diagram 0 (heating system only) Connections for diagram 0 and DHW Kit �� The optional kit is required to use this diagram Connections for diagram 1 (boiler) ��...
  • Page 23 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.23 Connections for diagram 3 (boiler + buffer tank) �� The optional kit is required to use this diagram Connections for home automation and gas boiler For all schemes to use the home automation contact or the gas boiler contact ��...
  • Page 24: Plumbing System Connections

    Plumbing must always be carried out by qualified personnel, able to carry out a state-of-the-art installation in compliance with the laws in force in the country of installation, after having read the next chapter. Ravelli denies all liabilities for damages to people or property arising from malfunctions due to failure to comply with this warning.
  • Page 25: Hydraulic Diagrams

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.25 Hydraulic diagrams With this thermo-stove, different types of system can be handled - both those where thermo-stoves are directly connected to heating circuits, and more complex systems with accumulators (Boilers, Buffer tanks or both) for DHW production. The hydraulic diagram to be used must be chosen via the display by an authorised technician when the thermo-stove is installed.
  • Page 26 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.26 Diagram 1 (boiler sensor) Diagram 1 allows operating a heating system where there is also a boiler for DHW production. The boiler can be connected to other heat production units, such as solar panels.
  • Page 27 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.27 Diagram 2 (buffer tank sensor) Diagram 2 can be used in a system where there is a buffer tank that operates the heating system and, if pre-set, also DHW produc- tion.
  • Page 28: System Water Characteristics

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.28 Diagram 3 (boiler sensor + buffer tank sensor) Diagram 3 is to be used in a system where both a water buffer tank for the heating system and a DHW boiler are present.
  • Page 29: Controls And Use

    Stove on/off button Handheld touch radio initialization The handheld, after a first short screen showing the Ravelli logo, will list the languages available in the menu. Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
  • Page 30: Description Of The Handheld Set

    AAA 1.5V) in the housing of the handheld set and observe the poles. Install the battery protective cover as shown in figure B. The handheld, after a first short screen showing the Ravelli logo, will list the languages available in the menu.
  • Page 31: Procedures For Use

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.31 ⚠ PROCEDURES FOR USE If the chimney catches fire you must call the fire brigade immediately. ⚠ Checks prior to start-up You have read and perfectly understood the contents of this instructions manual.
  • Page 32: Description Of The Display And Temperature Adjustment

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.32 ⚠ ⚠ The brazier could be very hot: danger of burns! Never empty the brazier inside the hopper. �� In stoves with self-cleaning brazier it is sufficient to reset the alarm and turn the stove back on: before loading more pellets, the stove will try to light any pellets already present in the brazier.
  • Page 33: Quick Status Display

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.33 Diagram 2 (buffer tank sensor) Indicates the water temperature of the storage puffer that you want to reach (if the thermostat is connected to the puffer, it indi- cates whether it requires heating the domestic water with ON t.ext. Or not with OFF t.ext.);...
  • Page 34: Operating Phases Of The Appliance

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.34 OPERATING PHASES OF THE APPLIANCE Sequence of ignition phases SWITCH-ON - initial pellet loading phase; WAIT FLAME - flame development wait phase;; FLAME PRESENT - flame stabilization phase and reduction of combustible inside the brazier;...
  • Page 35 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.35 The submenus of the USER MENU (the only one accessible for the end user) are the following: USER Menu VENTILATION VENTILATION Menu SET POWER Menu CHRONOTHERMOSTAT SET POWER Menu LOADING AUGER...
  • Page 36 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.36 By pressing the Increment key you can change each value and enable the days of the week; By pressing the Increment key you can change each value and enable the days of the week;...
  • Page 37 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.37 Stove status In this menu, you can check the correct operation of the most important parameters of the appliance. Below is a list of real stove data useful for the assistance service during the control phases.
  • Page 38: Setting

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.38 Select the type of Comfort Clima management on the water temperature or on the room tempera- ture using the UP or DOWN arrow keys DELAY DELAY SWITCH OFF SWITCH OFF...
  • Page 39: Anti-Condensation System

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.39 Setting > Season With this function it is possible to choose the WINTER or SUMMER season. In summer mode the stove works only to heat the DHW. WINTER Use the UP/DOWN keys to change the WINTER/SUMMER season.
  • Page 40: Stove Phase General Layout

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.40 Stove phase general layout Phase Description The stove is in the switch off phase and the cooling phase has not been completed FINAL CLEANING yet. SWITCH ON The heater pre-heating phase has started and the pellets start to fall into the grate.
  • Page 41 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.41 Phase Description The stove is off When the switch-on request from ECO-STOP mode coincides with an automatic WAIT FOR PELLETS switch-off condition (from the TIMER), the stove turns on ensuring total cleaning of OUT OF the brazier before switching to FINAL CLEANING.
  • Page 42 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.42 Warning Pop -Up Anomaly Description RDS SYSTEM REGULATION ADJUST It shows that the testing procedure and initial parameter calibration have been REQUEST completed incorrectly. (only if the RDS system is SYSTEM This indication, however, does not block the stove.
  • Page 43 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.43 Alarms (table with reference codes) Cod. Title Reason Solution Press the switch off key and switch on the stove again AL 01 BLACK OUT No voltage during work phase If the problem persists, contact the Support...
  • Page 44 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.44 Cod. Title Reason Solution The fume exhaust system has a loss of FUME EXHAUST AL 12 performance due to fan obstruction or voltage Contact the Support Service SYSTEM drop. AL 14 AUGER PHASE...
  • Page 45: Maintenance

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.45 MAINTENANCE ⚠ Safety warnings for maintenance Maintenance of the stove must be performed at least once a year and should be planned in advance with the Technical ⚠ Assistance Service.
  • Page 46: Extraordinary Maintenance

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.46 Cleaning the turbulators During operation, dust and soot are deposited on the surface of the heat exchanger tubes. To ensure smooth operation throughout the season, it is advisable to periodically clean the heat exchanger when the stove is cold.
  • Page 47: Failure Cases

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.47 Failure cases Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty Load the pellets into the tank AL 06 Empty the tank to check that no objects have...
  • Page 48 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.48 Problem Causes Possible remedies Alarm signal AL 05 The pellet tank is empty. Load the pellets into the tank AL 06 AL 05 Pellet is not loaded See previous problem...
  • Page 49 Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.49 Problem Causes Possible remedies Alarm signal Remote control not associated Pair the remote control to the stove following with the stove the instructions given here Evaluate the presence of other radio devices...
  • Page 50: Storage And Disposal

    Rev.0 18/05/2021 Use and maintenance manual Touch Radio Hydro Pag.50 STORAGE AND DISPOSAL Disposal Demolition and disposal of the stove is under the exclusive liability and responsibility of the owner who must do so in accordance with the laws in force in the country of installation pertaining to safety, respect and protection of the environment.
  • Page 51 ITA-Informazioni per la gestione di rifiuti di apparecchiature elettriche ed elettroniche contenenti pile e accumulatori Questo simbolo che appare sul prodotto, sulle pile, sugli accumulatori oppure sulla loro confezione o sulla loro documentazione, indica che il prodotto e le pile o gli accumulatori inclusi al termine del ciclo di vita utile non devono essere raccolti, recuperati o smaltiti assieme ai rifiuti domestici.
  • Page 52 ESP-Información para la gestión de residuos de aparatos eléctricos y electrónicos con pilas y acumuladores Este símbolo que aparece en el producto, en las pilas, los acumuladores o en su embalaje o su documentación indica que el producto y las pilas o acumuladores que contiene, al final de su vida útil, no deben recogerse, recuperarse o desecharse junto con los residuos domésticos.
  • Page 56 Aico S.p.A. Headquarter Via Consorzio Agrario, 3 - 25032 Chiari (BS) - Italy Research and Development Centre Viale del commercio 12/a - 37135 Verona (VR) - Italy T. + 39 030 7402939 info@ravelligroup.it FB Ravellifuocointelligente IG ravellistufe www.ravelligroup.it Aico S.p.A. does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice.

Table of Contents