Push Notification - WiFi Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for NCD PR60-12 MIRCC8 WIFI

  • Page 1 ATIONAL ONTROL EVICES Push Notification - WiFi Quick Start Guide...
  • Page 2 N A T I O N A L C O N T R O L D E V I C E S Push Notification WiFi Quick Start Guide National Control Devices, LLC PO Box 455 Osceola, MO 64776 Phone 417.646.5644 • Fax (866) 562-0406 ©...
  • Page 3: Table Of Contents

    T able of Contents Introduction ................1 What is the Push Notification Series?............1 What can this device be used for? ............1 How do Push Notification series products work? ........1 Getting Started ................. 2 WiFi Module Configuration .............. 2 WiFi Network Setup ..................
  • Page 4 Advanced Configuration ............10 Input Configuration.................. 10 User Definable Transmitted Bytes ............11 Troubleshooting ..............12 Technical Support ..............13 Contact Information ............... 14 Notice: ..................... 14...
  • Page 5: Introduction

    Chapter Introduction What is the Push Notification Series? The push notification series was designed for customers requiring contact closure input monitoring via push notification rather than a query based method. This means your application is free to process other tasks while listening for input status change.
  • Page 6: Getting Started

     A windows based computer (XP, 7, or 8) WiFi Network Setup Step 1: Install the Wi-Fi module into the WiFi Module Configuration board (Zigmo) Step 2: Connect USB cable from Zigmo board to computer Step 3: Install NCD Base Station Software for configuration/testing purposes...
  • Page 7 Step 4: Launch NCD Base Station Software. On the Select Connection window that appears click the drop down menu under com port, select the USB Serial port which was created when the Zigmo board was connected to the computer. Make sure Baudrate is set to 115200.
  • Page 8: Tcp Notification Setup

    TCP Notification Setup Select the Send Notification via TCP radio button. A window will appear allowing you to enter the destination IP address and Port Number. A listener application will need to be present at that location listening on the specified port number. UDP Notification Setup Select the Send Notification via UDP radio button.
  • Page 9: Initial Testing

    Initial Testing Step 9: (This will only work if the module was configured for UDP broadcast or if this is done on the computer specified as the server IP). For testing purposes open Base Station once more on a windows computer connected to the same network as the PN controller.
  • Page 10: Hardware Reference

    Chapter Hardware Reference Compatible Sensors (Understanding Inputs) Warning Users must NEVER apply any voltage to an input on PM series product! Inputs are for dry contact closures only! Inputs are capable of reading Contact Closure generating devices such as buttons and switches. A wire connected from the ground terminal to the input terminal would trigger in the input, as this would be considered a contact closure.
  • Page 11: Environmental Specifications

    Break Away tabs are useful in applications where space may be a concern. This allows your MirC to offer the same functionality in the smallest possible profile. Break Away tabs are unique to the NCD product line and are a standard option for most devices released in 2010 and later.
  • Page 12: Communication Overview

    Chapter Communication Overview Sensor Packet Breakdown The packet transmitted by the controller contains 22 bytes of data. Below is a breakdown of the packet: Byte Position Byte 10-17 Data Header F. ver User Status Prior Current Type Def. Type state state Byte 0 is a header byte.
  • Page 13: Direct Query Command Set

    Direct query command set The only command required for this product is to query the status of the inputs if needed. This may need to be done after a server reboot in order to get the current status of inputs on the controller. This will be done via a TCP socket connection to the controller’s IP address on the port number configured in the Listening Port field during WiFi module setup in Base Station.
  • Page 14: Advanced Configuration

    Chapter Advanced Configuration Input Configuration Inputs on PN series controller can be configured to send notifications when the input is opened or closed, only when they are closed, or only when they are opened. This configuration is done through Base Station as follows: Step 1: Open Base Station, Select the Network Radio button on the Select Connection window.
  • Page 15: User Definable Transmitted Bytes

    User Definable Transmitted Bytes 8 bytes in the Notification packet are definable by the user. These bytes can be used in any way required by the user. Configuration of these bytes is done using Base Station as follows: Step 1: Open Base Station;...
  • Page 16: Troubleshooting

    Chapter Troubleshooting Zigmo device does not appear in drop down Com Port box in Base Problem: Station. Make sure USB cable is good. USB LED on Zigmo should be on solid. If Fix: not download driver from FTDI here: http://www.ftdichip.com/Drivers/CDM/CDM20830_Setup.exe WiFi module will not associate with network.
  • Page 17: Technical Support

    Technical Support echnical support is available through our website, controlanything.com. AccessNCD is the way we connect NCD engineers to our customers. Click on the AccessNCD button located on the top right of the header of each page of our website.
  • Page 18: Contact Information

    Our engineers monitor questions and respond continually throughout the day. Before requesting telephone technical support, we ask that customers please try to resolve their problems through AccessNCD first. However, for persistent problems, NCD technical support engineers will schedule a phone consultation. Contact Information National Control Devices, LLC...