Heater Part Numbers: CRHEATER200A00 through CRHEATER263A00
Single Point Box Part Numbers: CSINGLE028A00 through CRSINGLE036A00
HEATER PACKAGE CONTENTS
ITEM
Heater Module
Wiring Label
SINGLE POINT BOX PACKAGE CONTENTS
ITEM
Single Point Box
Terminal Block
Wiring Label
Fuse Block†
* Quantity varies by kit.
† If single point box has fuses, contents will include a hinged cover,
rivets, and magnetic latch.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Heater Installation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Single Point Box
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring ComfortLinkt Control
SAFETY CONSIDERATIONS
Improper
installation,
adjustment,
maintenance, or use can cause explosion, fire, electrical shock, or
other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory−authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for brazing operations. Have fire extinguisher
available. Read these instructions thoroughly and follow all
warnings or cautions attached to the unit. Consult local building
codes and National Electrical Code (NEC) for special
requirements.
Recognize safety information. This is the safety−alert symbol
.
When you see this symbol on the furnace and in
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety−alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which may result in minor personal
Installation Instructions
QUANTITY
1
1
QUANTITY
1
*
1
*
. . . . . . . . . . . . . . . . . . . . . . . .
1-31
. . . . . . . . . . . . . . . . .
alteration,
service,
injury or product and property damage. NOTE is used to
highlight suggestions which will result in enhanced installation,
reliability, or operation.
!
ELECTRICAL OPERATION HAZARD
Failure to follow this caution may cause personal injury and
damage to equipment.
Field modification of electric heat staging may result in the
overriding of electric heat safety switches and is prohibited.
!
1
PROPERTY DAMAGE HAZARD
1
Failure to follow this caution may result in property
damage.
1
When removing panels from the unit, be careful not to
damage the roof or other surfaces with the panels.
4
4
This
installation
CRHEATER200A00 through CRHEATER263A00. A single
point box may be required for some heaters. The single point box
must be ordered separately when required.
Heater Installation
Perform the following procedure to install the accessory electric
heaters:
1. Turn off power to the unit. Install "Lock−Out Tag−Out"
tag on unit disconnect or breaker.
2. Configure unit for horizontal duct configuration, if
desired.
NOTE: The 50PG16 size requires an accessory conversion kit
for converting from vertical to horizontal duct configuration.
3. Permanently mark the appropriate block on the unit
nameplate for the accessory heater installed.
4. Verify unit input power wire sizing and circuit protection
per requirements on the unit nameplate for the accessory
heater installed.
5. Open the electric heater section, compressor section, and
indoor fan section access doors. (See Fig. 1.)
CAUTION
CAUTION
GENERAL
instruction
covers
accessory
INSTALLATION
heaters

Advertisement

loading

Summary of Contents for Carrier 50PG03-16

  • Page 1 4. Verify unit input power wire sizing and circuit protection per requirements on the unit nameplate for the accessory heater installed. 5. Open the electric heater section, compressor section, and indoor fan section access doors. (See Fig. 1.) CAUTION CAUTION...
  • Page 2 Check that the heater flange is straight and flat before installing. 8. Secure electric heater to unit using screws from item 6. Heater will attach to the block off plate screw holes.
  • Page 3 Fig. 2 − Block−Off Plate ROUTE HEATER POWER WIRES BEHIND SINGLE POINT BOX COMPRESSORS AS SHOWN. (COMPRESSORS REMOVED FOR CLARITY) Fig. 3 − Electric Heater Installation BLOCK-OFF PLATE MANUAL RESET LIMIT SWITCH ACCESSORY ELECTRIC HEATER ASSEMBLY C06183 C06184...
  • Page 4: Unit Voltage

    (default is No Heat). In addition, if a single-stage electric heater has been installed, it will be necessary to change the N.HTR configuration (2 is the default setting). These configurations are changed through the Scrolling Marquee Display or a Carrier network device. C06185...
  • Page 5: Thermostat Control

    Marquee Display or Navigator™ accessory. 1. The ComfortLink control must be configured to use the electric heater accessory. A password may be required to edit the configurations depending on the previous settings configured in the unit. Default password is “1111.”...
  • Page 6: Fuse Block

    FUSE BLOCK HINGED COVER TERMINAL BLOCK C06190 Fig. 9 − Single Point Box CRSINGLE033A00 FUSE BLOCK HINGED COVER TERMINAL BLOCK C06191 Fig. 10 − Single Point Box CRSINGLE034A00 TERMINAL BLOCK C06192 Fig. 11 − Single Point Box CRSINGLE035A00...
  • Page 7 FUSE BLOCK TERMINAL BLOCK Fig. 12 − Single Point Box CRSINGLE036A00 UNIT CONTROL BOX UNIT POWER PIGTAILS SINGLE POINT BOX HEATER WIRES SUPPLIED WITH HEATERS FIELD POWER HEATERS FUSE BLOCK Fig. 13 − Heater Wiring CRSINGLE028A00 HINGED COVER UNIT CONTROL BOX UNIT POWER PIGTAILS SINGLE POINT BOX...
  • Page 8 UNIT CONTROL BOX UNIT POWER PIGTAILS SINGLE POINT BOX HEATER WIRES SUPPLIED WITH HEATERS HEATERS FUSE BLOCK Fig. 15 − Heater Wiring CRSINGLE030A00 UNIT CONTROL BOX UNIT POWER PIGTAILS SINGLE POINT BOX HEATER WIRES SUPPLIED WITH HEATERS HEATERS FUSE BLOCK FUSE BLOCK Fig.
  • Page 9 UNIT CONTROL BOX UNIT POWER PIGTAILS SINGLE POINT BOX HEATER WIRES SUPPLIED WITH FIELD HEATERS POWER HEATERS FUSE BLOCK 40,50,60 kW ONLY FUSE BLOCK Fig. 19 − Heater Wiring CRSINGLE033A00 Fig. 20 − Heater Wiring CRSINGLE034A00 Fig. 21 − Heater Wiring CRSINGLE035A00 C06200 Fig.
  • Page 10 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER 50PG SUPPLY VOLTS−PH−HZ 208/230-1-60 12.8 208/230-1-60 15.4 208/230-3-60 11.5 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 11 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER SUPPLY 50PG VOLTS−PH−HZ 208/230-3-60 11.5 (cont) 460-3-60 (cont) 575-3-60 31.0 208/230-1-60 20.5 208/230-3-60 14.6 ELECTRIC HEAT POWER EXHAUST TYPE CPHEATER NOMINAL PART NO.
  • Page 12 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) POWER UNIT SUPPLY 50PG VOLTS−PH−HZ 208/230-3-60 187 253 14.6 (cont) 460-3-60 414 506 (cont) 575-3-60 518 632 34.0 LEGEND − Full Load Amps HACR −...
  • Page 13 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 208/230-1-60 187 253 26.9 208/230-3-60 187 253 17.6 460-3-60 414 506 ELECTRIC HEAT POWER EXHAUST CPHEATER NOMINAL TYPE PART NO.
  • Page 14 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 575-3-60 518 632 (cont) 208/230-3-60 187 253 20.5 460-3-60 414 506 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 15 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA.) UNIT IFMF POWER SUPPLY 50PG VOLTS-PH-HZ 575-3-60 54.0 (cont) 208/230-3-60 13.5 460-3-60 575-3-60 30.0 ELECTRIC HEAT POWER EXHAUST TYPE CRHEATER NOMINAL PART NO. 221A00 10.0 222A00...
  • Page 16 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA.) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 575-3-60 30.0 (cont) (cont) 208/230-3-60 16.0 460-3-60 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 17 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA.) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 460-3-60 414 506 (cont) (cont) 575-3-60 518 632 37.0 10.2 208/230-3-60 187 253 17.6 10.2 460-3-60 414 506 ELECTRIC HEAT POWER EXHAUST...
  • Page 18 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA.) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 575-3-60 518 632 40.0 (cont) LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 19 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA.) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 10.2 15.0 208/230-3-60 187 253 22.4 10.2 15.0 460-3-60 414 506 10.6 575-3-60 518 632 10.6 59.0 ELECTRIC HEAT POWER EXHAUST...
  • Page 20 Table 1 — Electrical Data — Units Without Optional Powered Convenience Outlet (cont) VOLTAGE COMPR COMPR COMPR NOMINAL RANGE NO. 1 NO. 2 NO. 3 UNIT POWER 50PG SUPPLY (V-PH-HZ) 208/230-3-60 187 253 18.1 137 18.1 137 17.6 123 1.9 460-3-60 414 506 575-3-60...
  • Page 21 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 208/230-1-60 187 253 12.8 208/230-1-60 187 253 15.4 208/230-3-60 187 253 11.5 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 22 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 208/230-3-60 11.5 (cont) 460-3-60 575-3-60 31.0 208/230-1-60 187 20.5 208/230-3-60 187 14.6 ELECTRIC HEATC POWER EXHAUST TYPE CRHEATER NOMINAL PART NO.
  • Page 23 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE (EA) UNIT POWER 50PG SUPPLY VOLTS-PH-HZ 208/230-3-60 14.6 (cont) 460-3-60 (cont) 575-3-60 34.0 208/230-1-60 26.9 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 24 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 208/230-1-60 26.9 (cont) 208/230-3-60 17.6 (cont) 460-3-60 575-3-60 40.0 ELECTRIC HEAT POWER EXHAUST TYPE CRHEATER NOMINAL PART NO. 201A00 17.3/ 20.0 3.8/ 5.0...
  • Page 25 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE NOMINAL COMPRESSOR RANGE POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 208/230-3-60 187 253 20.5 460-3-60 414 506 LEGEND − Full Load Amps HACR − Heating, Air Conditioning and Refrigeration −...
  • Page 26 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE COMPRESSOR NOMINAL RANGE UNIT POWER SUPPLY 50PG VOLTS-PH-HZ 575-3-60 518 632 54.0 (cont) 208/230-3-60 187 253 13.5 460-3-60 414 506 ELECTRIC HEAT POWER SUPPLY POWER EXHAUST TYPE CRHEATER NOMINAL...
  • Page 27 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE NOMINAL COMPRESSOR RANGE POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 575-3-60 518 632 30.0 (cont) 575-3-60 518 632 30.0 10.2 208/230-3-60 187 253 16.0 10.2 460-3-60 414 506 LEGEND −...
  • Page 28 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE NOMINAL COMPRESSOR RANGE POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 460-3-60 414 506 (cont) (cont) 575-3-60 518 632 37.0 10.2 208/230-3-60 187 253 17.6 10.2 460-3-60 414 506 ELECTRIC HEAT POWER EXHAUST...
  • Page 29 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE NOMINAL COMPRESSOR RANGE POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 460-3-60 414 506 (cont) (cont) 575-3-60 518 632 40.0 10.2 208/230-3-60 187 253 22.4 15.0 LEGEND − Full Load Amps HACR −...
  • Page 30 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE NOMINAL COMPRESSOR RANGE POWER UNIT SUPPLY 50PG VOLTS-PH-HZ 10.2 208/230-3-60 187 253 22.4 (cont) 15.0 460-3-60 414 506 10.6 (cont) 575-3-60 518 632 10.6 59.0 See legend pg. 32. ELECTRIC HEAT POWER EXHAUST...
  • Page 31 Table 2 — Electrical Data — Units With Optional Powered Convenience Outlet (cont) VOLTAGE COMPR COMPR COMPR NOMINAL RANGE NO. 1 NO. 2 NO. 3 UNIT POWER 50PG SUPPLY (V-PH-HZ) 208/230-3-60 187 253 18.1 137 18.1 137 17.6 123 1.9 460-3-60 414 506 50 1.0...
  • Page 32 % Voltage Imbalance = 100 x Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Example: Supply voltage is 460-3-60 Determine maximum deviation from average voltage.