Download Print this page

Ducane 2HP14 Specification Sheet

Split system heat pump

Advertisement

Quick Links

Split System Heat Pump
2 hp14
Features
L Model
• Durable scroll compressors,
with internal pressure
relief valves and inherent
thermal protection
• High-quality condenser
coil with copper tubing
and enhanced louvered
fin for maximum heat
transfer capacity
• Top discharge directs hot
air and sound away from
living area and shrubbery
• All units run tested
• Available with louvered
panel or wire guard coil
protection option
• Easy access to electrical
panels, pre-wired for easy
hook-up
B Model
14
• Hinged control panel allows
simple access to internal
components
• Bi-directional liquid line
filter drier factory installed
• Discharge muffler for
quiet operation
• Integrated LED diagnostics is
a reliable, solid state
time / temperature defrost
control, with field selectable
30/60/90 minute intervals
and is Quiet Shift™ capable
to reduce noise
• Low pressure switch for loss
of charge protection (factory
installed)
• Short cycle protection
(factory installed)
• All units ETL, ETLC approved
and ARI listed
• Charged for 15 feet of
interconnecting tubing
• Warranties:
10 year limited parts warranty
available (5 year compressor).
See limited warranty document
for details.
seer

Advertisement

loading

Summary of Contents for Ducane 2HP14

  • Page 1 Split System Heat Pump 2 hp14 Features • Durable scroll compressors, with internal pressure relief valves and inherent thermal protection • High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity • Top discharge directs hot air and sound away from living area and shrubbery • All units run tested • Available with louvered panel or wire guard coil protection option • Easy access to electrical panels, pre-wired for easy hook-up L Model • Hinged control panel allows simple access to internal components • Bi-directional liquid line filter drier factory installed • Discharge muffler for quiet operation • Integrated LED diagnostics is a reliable, solid state time / temperature defrost control, with field selectable 30/60/90 minute intervals and is Quiet Shift™ capable...
  • Page 2: Model Number Guide

    2HP14 Split System Heat Pump Model Number Guide Refrigerant – 2 = R22 AC = Condenser HP = Heat Pump 14 - 14 SEER Nominal Family / Coil Protection B = Non-Louvered L = Louvered Electrical and Physical Data Voltage/ Hz/ Voltage Model Phase Range 2HP14*18P 208-230/60/1 197 - 253...
  • Page 3 Cooling Performance with Evaporator Coils Indoor Model Outdoor Model Piston or Field Factory Installed TXV Installed TXV SEER 2HP14*24P E(C,H,M,U)1P29NA E(C,H,M,U)2T29NA 14.00 E(C,H,M,U)1P36N(A,B,C)+TXV E(C,H,M,U)2T36N(A,B,C) 13.50 2HP14*30P E(C,H,M,U)1P43NB+TXV E(C,H,M,U)2T43NB 13.50 E(C,M,U)1P48N(B,C)+TXV E(C,M,U)2T48N(B,C) 13.50 E(C,H,U)1P49NC+TXV E(C,H,U)2T49NC+TXV 14.00 2HP14*48P E(C,M,U)1P62ND+TXV E(C,H,U)2T62ND 14.00 E(C,H,U)1P62NC+TXV E(C,H,U)2T62NC 13.00 2HP14*60P E(C,H,U)1P62ND+TXV E(C,H,U)2T62ND 13.00...
  • Page 4 2HP14 Split System Heat Pump Cooling Performance with Air Handlers and Furnaces 18, 24, 30 Indoor Model Outdoor Furnace Model Piston or Field Factory Installed TXV Installed TXV E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA CMPEV050,075 E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA MPGAV050,075 E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA CMPEV050,075 2HP14*18P E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA MPGAV050,075 RBCS2M18C*****P+TXV RBCS2M18C*****T ----- RBCS2M24V*****P+TXV ----- ----- E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA CMPEV050,075 E(C,H,M,U)1P29NA+TVX E(C,H,M,U)2T29NA MPGAV050,075...
  • Page 5 Indoor Model Outdoor Furnace Model Piston or Field Factory Installed TXV Installed TXV E(C,H,M,U)1P36NA+TVX E(C,H,M,U)2T36NA MPGAV075 E(C,H,M,U)1P36NB+TVX E(C,H,M,U)2T36NB CMPEV100 E(C,H,M,U)1P36NB+TVX E(C,H,M,U)2T36NB MPGAV100 2HP14*36P E(C,H,M,U)1P43NB+TVX E(C,H,M,U)2T43NB MPGAV100 E(C,M,U)1P48NB+TVX E(C,M,U)2T48NB MPGAV100 RBCS2M36C*****P+TXV RBCS2M36C*****T ----- RBCS2M36V*****P+TXV ----- ----- E(C,H,M,U)1P43NB+TVX E(C,H,M,U)2T43NB MPGAV100 E(C,H,U)1P49NC+TVX E(C,H,U)2T49NC...
  • Page 6 2HP14 Split System Heat Pump Cooling Performance with Extended Ratings Indoor Model Indoor Outdoor Temp Piston or Factory Model DB/WB Field Installed ˚F Installed 85/72 RBCS2M18C RBCS2M18C 80/67 2HP14*18P *****P+TXV *****T 75/63 85/72 RBCS2M24C RBCS2M24C 80/67 2HP14*24P *****P+TXV *****T 75/63 85/72 RBCS2M30C RBCS2M30C 80/67 2HP14*30P *****P+TXV *****T 75/63...
  • Page 7 Heating Performance with Extended Ratings The information below is for nominal CFM and 70° indoor dry bulb. Indoor Model Outdoor Piston or Factory Model Field Installed Btuh RBCS2M18C RBCS2M18C 2HP14*18P *****P+TXV *****T Btuh RBCS2M24C RBCS2M24C 2HP14*24P *****P+TXV *****T Btuh RBCS2M30C RBCS2M30C 2HP14*30P *****P+TXV *****T...
  • Page 8 All specifications and illustrations subject to change without notice and without incurring obligations. Form No. D2HP14B/L-100 (10/08) Where Used 2HP14*18, 24, 30, 36, 42, 48, 60 2HP14*18, 24, 30, 36, 42, 48, 60 Factory Installed on all models Factory Installed on all models 2HP14*18, 24, 30, 36, 42, 48, 60 2HP14*18, 24, 30...