A.O. Smith 300 Series Instruction Manual page 63

Residential gas water heaters. power vent/power direct vent gas models with direct spark ignition
Table of Contents

Advertisement

Possible Causes - Check/Repair
Confirm the water heater is full of water.
Confirm the powered anode wire connections are tight
and free of debris or moisture (i.e. rust, solder, metal pipe
shavings).
Confirm proper electrical ground to the water heater.
Inspect powered anode, clean/replace as needed.
NOTE: This Fault only applies to models with powered (non-
sacrificial) anodes.
Confirm the anode rod is not bent and shorting to the
tank.
Confirm the powered anode is free of contamination
between the anode top and surrounding metal (i.e.
solder, loctite, WD40).
Confirm proper electrical ground to the water heater.
Inspect powered anode, clean/replace as needed.
NOTE: This Fault only applies to models with powered (non-
sacrificial) anodes.
Confirm that the lower probe cable is plugged into the
CCB and the lower probe connector.
Measure resistance of probe to check for an open or
shorted circuit.
Inspect lower probe cable for damage.
Inspect the lower probe. Replace as needed.
Fault Messages.
Displayed Fault/Alert Message
0 days 0 hr 0 min ago
No water detected by Powered
Anode.
The control indicates a problem
with the anode protection. By
ACCEPT
Anode Shorted
0 days 0 hrs 0 mins ago
The Powered Anode is shorted to
earth ground or the tank.
The control indicates a problem
with the anode
Lower Temp Probe Open
0 days 0 hrs 0 mins ago
The indicated temperature probe
may be shorted or open.
Check connector and resistance
of probe.
63
No Water
Error Code: D6 -8
BACK
Error Code: CC -B
BACK
Error Code: 48-0