Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 41

Table of Contents

Advertisement

Pr.
551
PU mode operation command source
D013
selection
1434
IP address 1 (Ethernet)
N600
1435
IP address 2 (Ethernet)
N601
1436
IP address 3 (Ethernet)
N602
1437
IP address 4 (Ethernet)
N603
1438
Subnet mask 1
N610
1439
Subnet mask 2
N611
1440
Subnet mask 3
N612
1441
Subnet mask 4
N613
1427
Ethernet function selection 1
N630
1428
Ethernet function selection 2
N631
1429
Ethernet function selection 3
N632
1430
Ethernet function selection 4
N633
1426
Link speed and duplex mode selection
N641
1455
Keepalive time
N642
1431
Ethernet signal loss detection function
N643
selection
1432
Ethernet communication check time
N644
interval
1424
Ethernet communication network
N650
number
40
1. OUTLINE
1.4 Connection and parameter setting
Initial
Name
value
9999
192
168
50
1
255
255
255
0
5001
45237
9999
9999
0
3600 s
0
9999
1
Setting range
The PU connector is the command interface enabled
2
in the PU operation mode.
The USB connector is the command interface in the
3
PU operation mode.
4
The operation panel is the command interface enabled
in the PU operation mode.
The Ethernet connector is the command interface in
5
the PU operation mode.
USB automatic recognition
Basically, the operation panel (PU connector) is the
9999
command interface. When the USB connector is used,
it is the command interface.
0 to 255
0 to 255
Enter the IP address of the inverter to be connected to
Ethernet.
0 to 255
0 to 255
0 to 255
0 to 255
Enter the subnet mask of the network to which the
inverter belongs.
0 to 255
0 to 255
502, 5000 to
5002, 5006 to
5008, 5010 to
5013, 9999,
Set the application, protocol, etc.
34962, 44818,
45237, 45238,
47808, 61450
Set the communication speed and the communication
0 to 4
mode (full-duplex/half-duplex).
When no response is returned for an alive check
message (Keep Alive ACK) for the time (s) set in
1 to 7200 s
Pr.1455 multiplied by 4 elapsed, the connection will be
forced to be closed.
Signal loss detection
0
disabled
1
A warning (EHR) is output
for a signal loss.
2
A warning (EHR) and the
Alarm (LF) signal are
output for a signal loss
3
A protective function
(E.EHR) is activated for a
signal loss.
Ethernet communication is available, but the inverter
0
output is shut off in the NET operation mode.
Set the interval of the communication check (signal
loss detection) time for all devices with IP addresses in
the range specified for Ethernet command source
0.1 to 999.8 s
selection (Pr.1449 to Pr.1454).
If a no-communication state persists for the
permissible time or longer, the inverter output is shut
off.
9999
No communication check (signal loss detection)
1 to 239
Enter the network number.
Description
Set the availability of the
signal loss detection and
select the action when
Ethernet communication
is interrupted by physical
factors.