2 - 3 S E R V I C E N O T E S
1. When replacing parts or circuit boards, clamp the lead wires around terminals before soldering.
2. When replacing a high wattage resistor (more than 1W of metal oxide film resistor) in circuit
board, keep the resistor about 5mm away from circuit board.
3. Keep wires away from high voltage or high temperature components.
4. Keep wires in their original position so as to reduce interference.
2 - 4

HIGH VOLTAGE WARNING

Operation of monitor outside of cabinet or with back removed may cause a serious shock hazard,
Work on this modelshould only be performed by those who are thoroughly familiar with precautions
necessary when working on high voltage equipment.
Exercise care when servicing this chassis with power applied. Many B plus and high voltage
terminals are exposed which, if carelessly contacted, can cause serious shock or result in damage to
the chassis, Maintain interconnecting ground lead connections between chassis and picture tube
dag when operating chassis.
Certain HV failures can increase X-ray radiation. Monitor should not be operated with HV levels
exceeding the specified rating for the chassis type. The maximum operating HV specified for the
chassis used in this monitor is
26KV± 1KV
with a line voltage of 120/24OV AC.
supply.
It is important to maintain specified values of all components in the horizontal and high voltage
circuits and anywhere else in the monitor that could cause a rise in high voltage or operating supply
voltages.
No changes should be made to the original design of the monitor. Components shown in
the shaded areas on the schematic should be replaced with exact factory replacement parts. The use
of unauthorized substitute parts may create a shock, fire or other hazard.
To determine the presence of high voltage, use an accurate, high impedance, HV meter connected
between second anode lead and CRT dag grounding device.
System, remove static charge from it by connecting a 10K ohm resistor in series with an insulated
wire (such as a test probe) between picture tube dag and 2nd anode lead. (AC line cord disconnect-
ed from AC power outlet).
The picture tube used in this monitor employs integral implosion protection. Replace with tube
of the same type number for continued safety. Do not lift picture tube by the neck. Handle the
picture tube only after discharging the high voltage completely.
Higher voltage may also increase possibility of failure in HV