PFFY-P-VLEM-E,VLRM-E
Model
Water temp.
size
71°FDB / 59°FWB
(Rated kW)
21.5°CDB / 15°CWB
°F
°C
CA
23
-5.0
2.0
32
0.0
2.0
41
5.0
2.0
20
50
10.0
2.0
(2.2)
68
20.0
2.0
86
30.0
2.0
104
40.0
1.8
113
45.0
1.7
23
-5.0
2.5
32
0.0
2.5
41
5.0
2.5
50
10.0
2.5
25
(2.8)
68
20.0
2.5
86
30.0
2.5
104
40.0
2.2
113
45.0
2.1
23
-5.0
3.2
32
0.0
3.2
41
5.0
3.2
32
50
10.0
3.2
(3.6)
68
20.0
3.2
86
30.0
3.2
104
40.0
2.9
113
45.0
2.7
23
-5.0
4.1
32
0.0
4.1
41
5.0
4.1
40
50
10.0
4.1
(4.5)
68
20.0
4.1
86
30.0
4.1
104
40.0
3.6
113
45.0
3.4
23
-5.0
5.0
32
0.0
5.0
41
5.0
5.0
50
10.0
5.0
50
(5.6)
68
20.0
5.0
86
30.0
5.0
104
40.0
4.5
113
45.0
4.2
23
-5.0
6.4
32
0.0
6.4
41
5.0
6.4
63
50
10.0
6.4
(7.1)
68
20.0
6.4
86
30.0
6.4
104
40.0
5.7
113
45.0
5.3
73°FDB / 61°FWB
77°FDB / 64°FWB
23°CDB / 16°CWB
25°CDB / 18°CWB
SHC
CA
SHC
CA
1.6
2.0
1.7
2.1
1.6
2.0
1.7
2.1
1.6
2.0
1.7
2.1
1.6
2.0
1.7
2.1
1.6
2.0
1.7
2.1
1.6
2.0
1.7
2.1
1.5
1.8
1.6
1.9
1.5
1.7
1.5
1.8
1.9
2.6
1.9
2.7
1.9
2.6
1.9
2.7
1.9
2.6
1.9
2.7
1.9
2.6
1.9
2.7
1.9
2.6
1.9
2.7
1.9
2.6
1.9
2.7
1.7
2.3
1.8
2.4
1.7
2.2
1.7
2.3
2.4
3.3
2.5
3.5
2.4
3.3
2.5
3.5
2.4
3.3
2.5
3.5
2.4
3.3
2.5
3.5
2.4
3.3
2.5
3.5
2.4
3.3
2.5
3.5
2.2
3.0
2.3
3.1
2.1
2.8
2.2
2.9
3.0
4.2
3.1
4.4
3.0
4.2
3.1
4.4
3.0
4.2
3.1
4.4
3.0
4.2
3.1
4.4
3.0
4.2
3.1
4.4
3.0
4.2
3.1
4.4
2.8
3.7
2.9
3.9
2.7
3.5
2.8
3.7
3.8
5.2
3.9
5.5
3.8
5.2
3.9
5.5
3.8
5.2
3.9
5.5
3.8
5.2
3.9
5.5
3.8
5.2
3.9
5.5
3.8
5.2
3.9
5.5
3.5
4.6
3.6
4.9
3.4
4.3
3.5
4.6
4.7
6.6
4.8
6.9
4.7
6.6
4.8
6.9
4.7
6.6
4.8
6.9
4.7
6.6
4.8
6.9
4.7
6.6
4.8
6.9
4.7
6.6
4.8
6.9
4.3
5.8
4.5
6.2
4.2
5.5
4.3
5.8
Indoor air temp.
81°FDB / 66°FWB
82°FDB / 68°FWB
27°CDB / 19°CWB
28°CDB / 20°CWB
SHC
CA
SHC
CA
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.5
2.0
1.6
2.0
1.5
1.8
1.6
1.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.8
2.5
1.9
2.5
1.7
2.3
1.8
2.3
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.2
3.2
2.4
3.2
2.2
3.0
2.3
3.0
3.0
4.5
3.2
4.5
3.0
4.5
3.2
4.5
3.0
4.5
3.2
4.5
3.0
4.5
3.2
4.5
3.0
4.5
3.2
4.5
3.0
4.5
3.2
4.5
2.8
4.0
3.0
4.0
2.7
3.8
2.9
3.8
3.8
5.6
4.1
5.6
3.8
5.6
4.1
5.6
3.8
5.6
4.1
5.6
3.8
5.6
4.1
5.6
3.8
5.6
4.1
5.6
3.8
5.6
4.1
5.6
3.6
5.0
3.8
5.0
3.4
4.7
3.7
4.7
4.7
7.1
5.0
7.1
4.7
7.1
5.0
7.1
4.7
7.1
5.0
7.1
4.7
7.1
5.0
7.1
4.7
7.1
5.0
7.1
4.7
7.1
5.0
7.1
4.4
6.3
4.7
6.3
4.2
5.9
4.5
5.9
- 88 -
CA:Capacity(kW) , SHC:Sensible Heat Capacity(kW)
86°FDB / 72°FWB
90°FDB / 75°FWB
30°CDB / 22°CWB
32°CDB / 24°CWB
SHC
CA
SHC
CA
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.7
2.2
1.6
2.2
1.6
2.0
1.6
2.0
1.6
1.8
1.5
1.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
2.0
2.8
1.9
2.8
1.8
2.5
1.7
2.5
1.8
2.3
1.7
2.3
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.5
3.6
2.4
3.6
2.3
3.2
2.2
3.2
2.2
3.0
2.1
3.0
3.1
4.5
3.0
4.5
3.1
4.5
3.0
4.5
3.1
4.5
3.0
4.5
3.1
4.5
3.0
4.5
3.1
4.5
3.0
4.5
3.1
4.5
3.0
4.5
2.9
4.0
2.8
4.0
2.8
3.8
2.7
3.8
4.0
5.6
3.8
5.6
4.0
5.6
3.8
5.6
4.0
5.6
3.8
5.6
4.0
5.6
3.8
5.6
4.0
5.6
3.8
5.6
4.0
5.6
3.8
5.6
3.7
5.0
3.6
5.0
3.6
4.7
3.4
4.7
4.9
7.1
4.6
7.1
4.9
7.1
4.6
7.1
4.9
7.1
4.6
7.1
4.9
7.1
4.6
7.1
4.9
7.1
4.6
7.1
4.9
7.1
4.6
7.1
4.6
6.3
4.3
6.3
4.4
5.9
4.2
5.9
kcal/h=kW x 860 , BTU/h = kW x 3,412
SHC
1.6
1.6
1.6
1.6
1.6
1.6
1.5
1.5
1.8
1.8
1.8
1.8
1.8
1.8
1.7
1.6
2.3
2.3
2.3
2.3
2.3
2.3
2.1
2.1
2.8
2.8
2.8
2.8
2.8
2.8
2.7
2.6
3.6
3.6
3.6
3.6
3.6
3.6
3.4
3.3
4.4
4.4
4.4
4.4
4.4
4.4
4.2
4.0