TROUBLESHOOTING
CONDITION
CAUSE
Pump will not
1) Air leak on suction
prime
plumbing
2) Blocked/Restricted
intake hose
3) Filter cap
disengaged
3) Filter gasket
damaged/missing
Pressure drops/
1) Restriction on
fluctuates during
suction line
standard
2) Pump sucking air
operation
3) Plugged filter
4) Damaged regulator
22
REMEDY
1) Tighten/replace
fittings & hose
clamps. Verify suction
hoses are in good
condition
2) Remove blockage
from suction line,
ensure line is not
kinked
3) Lock filter cap into
position
4) Replace filter
gasket
1) Inspect tank and
suction lines and
remove restriction
2) Tighten fittings
3) Remove and
clean filter mesh and
housing
4) Remove regulator
stem and inspect for
broken parts/pieces
Ice Master
T-Series
®
CONDITION
CAUSE
Pressure gauge
1) Plugged with debris 1) Un-thread, check
not registering
Hand gun loses
1) Debris in hose or
pressure
nozzle
2) Pump losing prime
3) Pump pressure
dropping/fluctuating
Watch Instruction Videos:
www.youtube.com
Discover More Helpful Tips:
www.IceControlTraining.com
Version 1.4
English
REMEDY
and clean pressure
gauge
1) Un-thread nozzle
tip and clean
2) See Remedy for
'Pump will not prime
or loses prime'
3) See Remedy for
'Pressure drops/
fluctuates during
standard operation'
23