Alarm signal reset
• Stop the motor and switch off the lights.
• Press the G-key for at least 2 seconds.
Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.

Charcoal Filters

In the recirculation mode the charcoal filters absorb smells
and unwanted odours.
This filter cannot be washed or regenerated. It must be
replaced when the C appears on the display or at least
once every 4 months. The filter saturation alarm has to
be activated already before.
Enabling/Disabling the alarm signal
• In the recycling version hoods the filter saturation
alarm must be activated during the instal-lation or
later.
• Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the last
two segments of the motor LEDS are lit on the
display.
• By releasing the E-key the clock icon starts to
flash.
• Within 3 seconds press the D-key to activate/
deactivate charcoal filter saturation alarm.
• C-symbol lit - charcoal filter saturation alarm
ACTIVATED.
• C-symbol unlit - charcoal filter saturation alarm
DEACTIVATED.
To Remove the Charcoal Filters
• Open the upper panel by pressing the A-key for few
second (see Part USE).
• Remove the metal filters.
• Remove the saturated charcoal filter as indicated
(A).
• Fit the new filters as indicated (B).
• Put the metal grease filters in their seats.
This appliance can be a possible fire hazard if
the grease and charcoal filters are not cleaned
and replaced as recommended.