Venturi Adjustment; Flame Characteristics - Napoleon Haliburton GDS28-1NEA Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

9.2

venturi adjustment

This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER.
note:
It is important that the orifice is securely inserted into the venturi.
GDS28-1
NG
3/8" (9.5mm)
P
5/16" (7.9mm)
9.3

flame characteristics

It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
VENTURI
BURNER
PSE THERMOCOUPLE
ORIFICE
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
SIT ELECTRONIC IGNITION
3/8" - 1/2"
ADD IMAGE
(9.5mm - 12.7mm)
HERE
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
36.1
SIT MILLIVOLT
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
PSE LONG SENSOR
3/8" - 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
AIR
SHUTTER
OPENING
33.1
W415-4005 / A / 07.22.21
EN
(9
La flam
la therm
(9.5
La
la
(
La flam
la therm
(9.5
37