Sony KDL-32S3000 Service Manual page 7

Flat panel color tv
Hide thumbs Also See for KDL-32S3000:
Table of Contents

Advertisement

The identification of errors within the SE1A chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the
event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous
flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant
device number will be displayed through the LED (Series of flashes which must be counted).
LED Error Code
Number of LED
Flashes
02
03
04
05
06
07
08
09
10
11
12
13
14
Error Descriptions
Error Description
Balancer error.
Power supply protection error.
Panel error.
NVM error.
IIC error.
HDMI error.
Digital error.
Tuner Error
Sound processor
WCG port error
WCG IC error
RTC error
FRCH error
All manuals and user guides at all-guides.com
SE1A SELF DIAGNOSTIC SOFTWARE
Error Description
Balancer error.
Power supply protection error.
Panel error.
NVM error.
IIC error.
HDMI error.
Digital error.
Tuner Error
Sound processor
WCG port error
WCG IC error
RTC error
FRCH error (Only models with
FRCH)
Balancer error/PANEL_DET (PMUX6.7) to low level, between 2.48V and 0.83V.
5V, 3.3V or 1.8V failure/POWER_DET (P1_0) to high level.
Inverter failure/PANEL_DET (PMUX6.7) to low level, less than 0.83V.
EEPROM cannot be read or written.
IIC bus cannot be correctly initialised.
HDCP cannot be set-up correctly.
Digital CPU does not respond by DPI communication (Only for digital models).
IF circuit or PLL circuit does not respond to IIC commands.
MSP3410G IC does not respond to IIC commands.
FPGA has not been configured properly by HW.
FPGA Wide Colour Gamut device does not respond to IIC commands.
RTC IC does not respond to IIC commands (Only for digital models).
Only in FRCH models, when communication through IIC fails.
Checked
In normal mode.
In normal mode.
In normal mode.
In initialisation state.
In normal mode.
In initialisation state.
In normal mode.
In initialisation state.
In initialisation state.
In initialisation state.
In initialisation state.
In initialisation state.
In initialisation state.
Meaning/Related Fault
- 7 -
SE1A
RM-ED009
Action
Goes into standby.
Goes into standby.
Goes into standby.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.
Adds error to error menu.