Carrier 38AE012 Installation, Start-Up And Service Instructions Manual page 8

Air-cooled condensing units 50/60 hz
Table of Contents

Advertisement

UNIT
Model
Nameplate
501
208-230
201
38AE012
601
101
501
208-230
201
38AE014
601
101
501
208-230
201
38AE016
601
101
501
208-230
201
38AKS024
601
101
UNIT
Model
Nameplate
803
230
38AE012
903
400
803
230
38AE014
903
400
803
230
38AE016
903
400
803
230
38AKS024
303
346
903
400
FLA
— Full Load Amps (Fan Motors)
ICF
— Maximum Instantaneous Current Flow during start-up (LRA of compressor plus total FLA of fan motors)
kW
— Total Fan Motor Input (kilowatts)
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps per NEC (U.S.A.), Section 430-24
MOCP — Maximum Overcurrent Protection (amps)
RLA
— Rated Load Amps (Compressor)
*Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above
the listed limits.
NOTES:
1. The MCA and MOCP values are calculated in accordance with the National Electrical Code (NEC) article 440
(U.S.A. standard).
2. Motor RLA and LRA values are established in accordance with Underwriters' Laboratories (UL) Standard 1995
(U.S.A. standard).
Fig. 7 — Remote Thermostat Wiring
Table 5A — Electrical Data (3 Ph/60 Hz)
UNIT
Volts
Supplied*
MCA
Min
Max
187
253
62.5
380
342
418
35.0
460
414
528
29.1
575
518
660
22.8
187
253
69.3
380
342
418
38.0
460
414
528
31.7
575
518
660
25.6
187
253
87.5
380
342
418
49.3
460
414
528
40.7
575
518
660
33.0
187
254
93.4
380
342
418
49.7
460
414
508
48.1
575
518
632
40.1
Table 5B — Electrical Data (3 Ph/50 Hz)
UNIT
Volts
Supplied*
MCA
Min
Max
198
264
47.5
342
457
31.4
198
264
51.0
342
457
34.0
198
264
66.9
342
457
43.0
198
254
91.8
311
380
51.5
342
440
50.2
LEGEND
C
— Compressor Contactor
HD
— Heating Device
IFC
— Indoor-Fan Contactor
LLSV — Liquid Line Solenoid Valve
NOTES:
1. Combination LLSV plus IFC va should not exceed 30 va.
2. Do not exceed 5 va (24 vac) per coil.
3. If va values shown in Notes 1 and 2 must be exceeded, use
accessory relay transformer package 38AE900001.
COMPR
MOCP
ICF
RLA
(Fuse)
178
100
43.6
101
50
24.0
81
40
20.0
67
35
15.7
199
100
49.3
112
60
26.5
84
50
22.1
73
40
17.9
274
125
63.6
153
80
36.0
124
60
29.3
100
50
23.8
353
150
67.9
199
80
34.6
177
80
34.7
124
60
28.8
COMPR
MOCP
ICF
RLA
LRA
(Fuse)
134
75
32.9
128
80
50
20.0
74
149
75
35.7
143
89
50
22.1
83
206
100
47.9
200
121
60
29.3
115
213
150
67.9
207
121
80
33.3
115
179
80
34.6
173
8
LEGEND
R
FAN MOTORS (Single Phase)
FLA (ea)
Total
Fan No.
LRA
Fans
1
170
4.3
93
4.3
2
77
2.3
62
1.8
191
4.3
104
4.3
2
80
2.3
69
1.8
266
4.3
145
4.3
2
120
2.3
96
1.8
345
4.3
191
4.3
2
173
2.3
120
1.8
FAN MOTORS 230 v (Single Phase)
FLA (ea)
Total
Fan No.
Fans
1
2
2.9
3.5
2
2.9
3.5
2
2.9
3.5
2
2.9
3.5
Relay
Factory Wiring
Field Wiring
kW
2
3.7
3.7
1.41
1.9
1.8
3.7
3.7
1.41
1.9
1.8
3.7
3.7
1.41
1.9
1.8
3.7
3.7
1.41
1.9
1.8
kW
2
1.20
1.20
1.20
1.20