Summary of Contents for Quadlogic RSM-5c

  • Page 1 Table of Contents Manual 3-Phase kWh 3-Phase Demand Single-Phase kWh...
  • Page 2 Power Line Communications Metering Systems RSM-5c RSM-5 Installation Manual...
  • Page 3: Table Of Contents

    Fuse Block Connections Chapter 4 Menu Navigation Chapter 5 Verifying Meter Functionality Chapter 6 Resetting Demand Values (For “D” Models) Chapter 7 Reading the Display Chapter 8 Metering Specifications Chapter 9 Ordering Information Chapter 10 Miscellaneous © COPYRIGHT 2008 Quadlogic Controls Corporation...
  • Page 4 Thank you for purchasing a power meter manufactured by Quadlogic Controls Corporation. Quadlogic has been designing, manufacturing, and selling digital electric metering systems for over 25 years. We appreciate your business. ontaCt nformatIon For sales and technical support, please contact Quadlogic Controls Corporation as indicated below.
  • Page 5: Introduction

    Step 1: Mount the box The RSM-5c or RSM-5 back box is the enclosure for the meter head. The back box is supplied with the RSM-5c or RSM-5 fuse block installed in the box. 1. Choose a section of wall to mount the meter. This should be as close as possible to the distribution panel (preferably within 24”).
  • Page 6 3. Run the #12 AWG feeder phase tap wires through the conduit to the back box. 2. Mount the RSM-5c or RSM-5 back box to the wall, with mouting screws. Connect the distribution panel box to the RSM-5c or RSM-5 back box with a metal conduit.
  • Page 7: Fuse Block Connections

    - RSM-5c and RSM-5 Installation - Chapter 2 The following diagrams show the necessary fuse block connections for RSM-5 and RSM-5c meters. Figures 3-1, 3-2, and 3-3 show RSM-5c 3-phase 4-wire wye, 3-phase 3-wire delta, and 1-phase 3-wire (120/208V, 120/240V, or 277/480V network configuration) respectively.
  • Page 8 For use with 5 Amp secondary CTs. Figure 3-5. RSM-5 3-Phase 3-Wire Delta with High Current Adapter (HCA). Figure 3-3. 1-Phase 3-Wire 120/240V, 120/208V, or 277/480V Network Fuse Block Connections. For use with 5 Amp secondary CTs. © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 9 - Fuse Block Connections - Chapter 3 Figure 3-6. RSM-5 3-Phase 4-Wire Wye with High Current Adapter (HCA). All CTs must be the same primary amperage and secondary amperage must be 5 Amp. © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 10: Menu Navigation

    -Menu Navigation - Chapter 4 The RSM-5c and RSM-5 user interface (LCD window) is located on the front Releasing the display scroll button at a given menu heading will allow the panel of the meter. It is easy to navigate the various sub-menus to read user to cycle through the registers listed under the selected menu heading as metering data, reset values and view configuration data. See Figure 4-1.
  • Page 11 -Menu Navigation - -Menu Navigation - Chapter 4 Chapter 4 Figure 4-4. Display Menu Structure For an RSM-5c and RSM-5 Meter. © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 12: Verifying Meter Functionality

    Verifying Meter Functionality - Verifying Meter Functionality - Chapter 5 It is very important to verify that the CTs of the RSM-5c and RSM-5 are III. Verifying Current and Power properly installed. Follow the steps below to verify the voltage, kWh reading, current, and power.
  • Page 13: Resetting Demand Values (For "D" Models)

    Use the following procedure to reset the Demand registers to zero: 1. Press and hold the Demand Reset button shown in Figure 4-1. 2. The LCD will initially display the Quadlogic Copyright message. 3. The LCD will then display the Dmdreset event screen: 4.
  • Page 14: Reading The Display

    Example: Meter point with 400:0.1A CT LCD reading for meter is 3422.119kWh Table 7-1. Multiplier table for RSM-5c and RSM-5 meter with 0.1 AMP CTs. “XXX” represents voltage. The correct cumulative consumption (kWh) for this meter is 13688.476 kWh. (400 ÷ 100 = 4. Multiply face value, for consumption and demand values by 4.
  • Page 15: Metering Specifications

    Time-of-Use (TOU): Memory: • Up to 16 blocks per day available for all metering parameters (Exception: • 512 kilobyte non-volatile flash memory retains daily and interval data Pulse input data received by the RSM-5c and RSM-5 are not available in • During power outage: time-of-use blocks.) - Flash memory retains daily and interval data - Long-life lithium battery maintains time, logs incoming pulses and retains...
  • Page 16: Ordering Information

    Chapter 8 Environment: Meter Kits (CTs included)……………pages 25-28 • Enclosure: NEMA 1 rated for indoor use only. (Outdoor NEMA 4X optional.) Meter Kits are available for the RSM-5c and RSM-5 products and include the • Temperature: -20˚C to +60˚C complete meter assembly (meterhead, fuse block and back box) as well as the • Humidity: 0-95% relative humidity (non-condensing) required current transformers (CTs) for operation.
  • Page 17 -Ordering Information - -Ordering Information - Chapter 9 Chapter 9 RSM-5c Meter Kits: kWh Meters RSM-5 Meter Kits: kWh for Large Service Meters Kits include meterhead, fuse block, back box and required current transformers. Enclosure: 6.9”H X 9.8”W X 4.9”D For 1600Amp &...
  • Page 18 Figure 3-6 6 SPLIT CORE RSM5 277100-6D 277/480V √√ RSM5 277200-6D 277/480V √√ RSM5 277400-6D 277/480V √√ All meters have built-in Power Line Communications capability. All meters have built-in Power Line Communications capability. © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 19 3-Phase Meter – DELTA (“DTA”) Catalog # Volts Amps kWh Only kWh & kWh, Demand & Diagram Demand** 4 Pulse Inputs** RSM5c 480DTA √ RSM5c 480DTA D 0.1A 480V √√ Figure 3-2 RSM5c 480DTA PD √√√ © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 20 Demand & kWh, Demand & Diagram Modem** RS - 485** 4 Pulse Inputs** RSM5 480DTA01A D √√ RSM5 480DTA01AMD √√√ 480V 0.1A Figure 3-2 RSM5 480DTA01ARSD √√√ RSM5 480DTA01A PD √√√ © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 21 **Standard Configuration for Demand models ("D"): kWh register, peak demand (kW) register with date and time stamp and 15-minute data logging (intervals). Customized programming available for demand models only. Contact Manufacturer for details. © COPYRIGHT 2008 www.quadlogic.com © COPYRIGHT 2008 www.quadlogic.com...
  • Page 22: Miscellaneous

    Notable Revision History Obligation under this warranty is limited to repair and/or replacement, at Quadlogic’s option, of the manufactured product and in no event shall Quadlogic DATE PAGE DESCRIPTION be liable for consequential or incidental damages.
  • Page 24 QUADLOGIC 33-00 Northern Blvd. Long Island City, NY 11101 Tel (212) 930-9300 Fax (212) 930-9394 www.quadlogic.com RSM5/5c MANR2.0.R...
  • Page 25 3-Phase kWh...
  • Page 28 3-Phase Demand...
  • Page 31 Single-Phase kWh...