Check For Leaks - GE JGRS06BEJ Installation Instructions Manual

24” gas built-in oven
Hide thumbs Also See for JGRS06BEJ:
Table of Contents

Advertisement

Available languages

Available languages

GAS CONNECTIONS (cont.)
5
I
Place the oven in the cutout.
J
Level the oven:
1. Place a spirit level on one of the oven
racks.
2. If the oven is not level, adjust the leg
levelers.
With the oven in place, remove the regulator
cover by carefully grasping the left side and
pull until the spring clip is released. The
pressure regulator inlet is accessible through
the opening in the main back.
K
Remove regulator cover.
L
Through this opening connect:
1. The flexible connection and the adaptor
(see Fig. 7).
or
2. The rigid pipe connection and union to the
shutoff valve (see Fig. 8).
Tighten the fitting.
M
Pressure Regulator
Fig. 7
FLEXIBLE HOOK-UP
Pressure Regulator
Fig. 8
RIGID HOOK-UP
WARNING:
FORCING COULD DAMAGE THE FITTING,
TUBING OR CAUSE LEAKING.
Installation Instructions
Adaptor
Flexible
Connection
Regulator
Cover
Adaptor
Regulator
Cover
DO NOT FORCE!

CHECK FOR LEAKS

6
WARNING:
FLAME TO CHECK FOR LEAKS!
Apply a soap solution to all connections:
A
supply line, manifold and oven.
B
Turn on the main gas supply.
C
Check for any bubbles to form.
D
Turn off main gas supply.
Stop any leaks found.
E
Turn main gas supply on to make sure all
F
leaks were stopped.
WARNING:
STOPPED BEFORE ATTEMPTING TO LIGHT
BURNERS.
PRESSURE TEST INFORMATION
7
The maximum allowable pressure for the
A
regulator is 14" W.C.
B
The minimum pressure needed to check the
regulator setting is 11" W.C. for L.P. gas and
5" W.C. for Natural.
CAUTION:
individual shutoff valve must be
disconnected from the gas supply piping
system during any pressure testing of the
gas supply system at test pressures in
excess of 1/2 psig (pound per square inch
gauge).
The range must be isolated from the gas supply
piping system by closing its individual manual
shut-off valve during any pressure testing of the
gas supply system at test pressures equal to or
less than 1/2 psig.
5
DO NOT USE OPEN
ALL LEAKS MUST BE
The range and its

Advertisement

Table of Contents
loading