Table 4. Led Indicators - ADTRAN 239 HR Installation And Maintenance Manual

High-bit-rate digital subscriber line range extender
Table of Contents

Advertisement

LED
239 HRE
1246045L1
NET LP1 .................. This LED indicates the HDSL signal quality and errors on NET loop 1. The NET LP1 LED will flash
LP1
N
E
LP2
T
C
LP1
U
S
LP2
T
LL
RL
(Y)
(G)
NET LP2 .................. This LED indicates the HDSL signal quality and errors on NET loop 2. NET LP2 LED will flash once
CUST LP1 ................ This LED indicates HDSL signal quality, loopback status, and errors on CUST loop 1. It will flash
CUST LP2 ................ This LED indicates HDSL signal quality and errors on CUST loop 2. It will flash once when an
LL ...................................... Local Loopback. Indicates loopback from the HRE toward the network is active.
RL ...................................... Remote Loopback. Indicates loopback from the HRE toward the customer is active.
Loopback control codes are governed by the HTU-C (and HRE(s) if deployed). Standard or Enhanced loopback codes are
used dependent on the type of HTU-C deployed. See Appendix A for a more detailed description of Standard and Enhanced
loopback coding.
Note: If the signal quality is good and the pulse attenuation is bad, the LED will blink green. If the signal
quality is marginal and the pulse attenuation is good, the LED will be solid Yellow.
61246045L1-5B

Table 4. LED Indicators

Five tricolored faceplate LEDs indicate these HRE states.
Descriptions and Indications
once when an errored second is detected on NET loop 1. If the NET LP1 LED flashes yellow rapidly
(six times per second), sealing current is present and the HRE is attempting to synchronize with the
other HDSL circuit elements.
Off .......... No synchronization with the HTU-C.
Green ...... Synchronized with good signal quality on NET loop 1 (> 2 dB margin).
Yellow .... Synchronized with marginal signal quality on NET loop 1 (1 to 2 dB margin).
Red ......... Synchronized with poor signal quality on NET loop 1 (0 dB margin).
when an errored second is detected on NET loop 2.
Off .......... No synchronization with the HTU-C.
Green ...... Synchronized with good signal quality on NET loop 2 (> 2 dB margin).
Yellow .... Synchronized with marginal signal quality on NET loop 2 (1 to 2 dB margin).
Red ......... Synchronized with poor signal quality on NET loop 2 (0 dB margin).
once when an errored second is detected on CUST loop 1.
Off .......... No synchronization with the HTU-R.
Green ...... Synchronized with good signal quality on CUST loop 1 (> 2 dB margin).
Yellow .... Synchronized with marginal signal quality on CUST loop 1 (1 to 2 dB margin).
Red ......... Synchronized with poor signal quality on CUST loop 1 (0 dB margin).
errored second is detected on CUST loop 2.
Off .......... No synchronization with the HTU-R.
Green ...... Synchronized with good signal quality on CUST loop 2 (> 2 dB margin).
Yellow .... Synchronized with marginal signal quality on CUST loop 2 (1 to 2 dB margin).
Red ......... Synchronized with poor signal quality on CUST loop 2 (0 dB margin).
Section 61246045L1-5, Issue 2