SCA2001KSS – Above-the-Cooktop Advantium
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following
carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4" x 10"
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must
be used. Do not use less than a 6" diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align
exhaust with the space between studs, or wall should be prepared at the
time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
Filter Kit Accessory
Grille
Specification Created 9/05
240435
Oven
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
cannot be vented
to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4" x 10"
rectangular or 6" diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional
resistance to airflow and are equivalent to a section of straight duct
which is longer than their actual physical size. When calculating the
total duct length, add the equivalent length of all transitions and
adaptors plus the length of all straight duct sections. The chart below
shows the approximate feet of equivalent length of some typical ducts.
Equivalent Feet
Duct
A. Rectangular-To-round
5 ft.
Transition Adaptor
B. Wall Cap
40 ft.
C. 90° Elbow
10 ft.
D. 45° Elbow
5 ft.
E. 90° Elbow
25 ft.
F. 45° Elbow
5 ft.
G. Roof Cap
24 ft.