GE DSLVR48GH Installation Instructions Manual

Ge dslvr48gh: install guide

Advertisement

Quick Links

Installation
Instructions
If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)

BEFORE YOU BEGIN

Read these instructions completely and
carefully.
IMPORTANT-
instructions for local inspector's use.
IMPORTANT-
all governingcodes and ordinances.
Note to Installer
- Be sure to leave
these instructions with the customer.
Note to Customer
- Keep these
instructions with your Use and Care
Book for future reference.
• Before the old dryer is removed from
service or discarded, remove the dryer
door.
• Inspect the dryer exhaust outlet and
straighten the outlet walls if they are
bent.
• Service information and the wiring dia-
gram are located in the control console.
• Do not allow children on or in the
appliance. Close supervision of child-
ren is necessary when the appliance is
used near children.
• Install the dryer where the temp-
erature is above 50°F for satisfactory
operation of the dryer control system.
TOOLS YOU
WILL NEED
(x2)
10" ADJUSTABLE WRENCHES
8" PIPE WRENCH
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation
Specifications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
or Visit our Web site at: www. GEAppliances.com
WARNING
• To reduce the risk of severe injury or death, follow all installation instructions.
• Clothes dryer installation must be performed by a qualified installer.
• Install the clothes dryer according to these instructions and in accordance with
Save these
local codes. In the absence of local codes, installation must comply with National
Fuel Gas Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane
Installation Code, CSA B149.1.
Observe
• California Safe Drinking Water and Toxic Enforcement Act
This act requires the governor of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive harm and requires businesses to
warn customers of potential exposure to such substances. Gas appliances can cause minor
exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde
and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.
Properly adjusted dryers will minimize incomplete combustion. Exposure to these
substances can be minimized further by properly venting the dryer to the outdoors.
• This dryer must be exhausted to the outdoors.
• Use only 4" rigid metal ducting for exhausting the clothes dryer to the outdoors.
• DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible
metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed
in accordance with the instructions found in "Connecting The Dryer To House
Vent" on page 6 of this manual. Flexible ducting materials are known to collapse,
be easily crushed, and trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
• Do not install or store this appliance in any location where it could be exposed to
water and or weather.
• Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
In the state of Massachusetts, installation must be performed by a qualified
or licensed contractor, plumber, or gasfitter qualified or licensed by the state.
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
LEVEL
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)

Gas Dryer

08
RISK OF FIRE
MATERIALS YOU WILL NEED
4" DIAM METAL ELBOW
EXHAUST HOOD
(x2)
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
FLEXIBLE GAS LINE CONNECTOR
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
PIPE
COMPOUND
SOAP SOLUTION
FOR LEAK DETECTION
DUCT TAPE
SAFETY GLASSES
GLOVES

Advertisement

Table of Contents
loading

Summary of Contents for GE DSLVR48GH

  • Page 1: Gas Dryer

    • This dryer must be exhausted to the outdoors. • Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors. • DO NOT install a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed in accordance with the instructions found in "Connecting The Dryer To House...
  • Page 2: Installation Instructions

    NATIONAL FUEL GAS CODE, ANSI Z223. • This gas dryer is equipped with a Valve & Burner Assem- bly for use only with natural gas. Using conversion kit WE2 5X0217, your local service organization can convert this dryer for use with propane (LP) gas.
  • Page 3 3 RECONNECTING GAS Listed connector ANSI Z21.24 / CSA 6.10 FLARE 3/8" NPT Note: The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease, oil and thread sealant.
  • Page 4: Electrical Connection Information

    INJURY: • DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE. Dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, in accordance with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO.
  • Page 5: Exhaust Connection

    7 EXHAUST CONNECTION WARNING - TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY: • This clothes dryer must be exhausted to the outdoors. • Use only 4” rigid metal ducting for the home exhaust duct. Use only 4” rigid metal or UL-listed flexible metal •...
  • Page 6: Alcove Or Closet Installation

    LENGTH 9 ALCOVE OR CLOSET INSTALLATION • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION section.
  • Page 7 CAUTION: Be sure not to pull or damage the 9" • Apply duct tape as shown on the joint between the dryer internal duct and the elbow. PORTION "A" LEFT SIDE...
  • Page 8 THROUGH BOTTOM OF CABINET • Insert the elbow through the rear opening and connect it to the dryer internal duct. • Apply duct tape on the joint between the dryer internal duct and elbow, as shown on page 7. CAUTION:...

This manual is also suitable for: