3. Disassembly & Reassembly
3.1. Overall Disassembly & Reassembly
CAUTION
•
Be sure to separate the power cord before
disassembling the unit.
•
Discharge the capacitors first when separating PCB's
with high capacity capacitors such as SMPS, X
Main Board, Y Main Board, etc. (A spark may be
generated by the electric charge, and there is danger
of electronic shock.)
•
Check that the cables are properly connected
referring to the circuit diagram when disassembling
or assembling the unit taking care not to damage the
cables
•
Take care not to scratch the Glass Filter in the front.
•
Assemble the boards in the reverse order of the
disassembly.
•
The plasma must be layed down on a flat padded
surface for disassembly and reassembly.
Copyright© 1995-2011 SAMSUNG. All rights reserved.
1. Remove a screw of Inlet Cover.
6003–000337 : M4 * L10
2. Remove the Inlet Cover.
3. Push both side and pull the cord down to remove it
from the unit.
4. Place monitor face down on cushioned table.
3. Disassembly & Reassembly
3-1