Haier AS072XCEAA Operation & Installation Manual

Wall mounted type indoor units
Hide thumbs Also See for AS072XCEAA:

Advertisement

Quick Links

R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER
WALL MOUNTED TYPE INDOOR UNITS
OPERATION & INSTALLATION MANUAL
No. 0010577701
Please read this manual carefully before using this air conditioner.
Please keep this manual safely for future use.
All manuals and user guides at all-guides.com
AS072XCEAA
AS092XCEAA
AS122XCEAA
AS142XCEAA

Advertisement

Table of Contents
loading

Summary of Contents for Haier AS072XCEAA

  • Page 1 All manuals and user guides at all-guides.com R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER WALL MOUNTED TYPE INDOOR UNITS OPERATION & INSTALLATION MANUAL AS072XCEAA AS092XCEAA AS122XCEAA AS142XCEAA No. 0010577701 Please read this manual carefully before using this air conditioner. Please keep this manual safely for future use.
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com Contents Cautions ..................... Safety precautions................Parts and Functions ................Notes for safety ................... Operation and Maintenance ..............Trouble shooting ................9-10 Customer Need-to-know ..............Instructions to installation ............... 12-16 When trouble happens................Failure code ..................
  • Page 3: Cautions

    All manuals and user guides at all-guides.com Cautions Disposal of the old air conditioner Consult your local authorities for the name and address of the waste materials collecting Before disposing an old air conditioner centers and waste paper disposal services that goes out of use, please make sure it's nearest to your house.
  • Page 4 All manuals and user guides at all-guides.com Cautions All electrical repairs must be carried out 4. The wiring method should be in line with by qualified electricians. Inadequate repairs the local wiring standard. may result in a major source of danger for the user of the air conditioner.
  • Page 5: Safety Precautions

    All manuals and user guides at all-guides.com Safety precautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages;...
  • Page 6 All manuals and user guides at all-guides.com Safety precautions CAUTIONS! Don't operate the air-conditioner with damp Conditioner should not be used for any other hands. purpose other than airconditioning. Otherwise will be shocked. Don't use air-conditioner for any other special purposes, e.g.
  • Page 7 All manuals and user guides at all-guides.com Safety precautions CAUTIONS ON INSTALLATION Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard.
  • Page 8: Parts And Functions

    All manuals and user guides at all-guides.com Parts and Functions INDOOR UNIT FRONT VIEW Singal receiver window Air inlet grille Air filter (inside) Air outlet grille Louver INDOOR UNIT BACK VIEW Mounting plate Heat preservation pipe Connecting pipes Drainage pipes...
  • Page 9: Notes For Safety

    All manuals and user guides at all-guides.com Notes for safety Clean the dust filter periodically: Use the fuse of required capacity: Blockage of the dust filter would reduce the Never use steel wire or copper wire to take cooling and heating effect, consume more place of the fuse.
  • Page 10: Operation And Maintenance

    All manuals and user guides at all-guides.com Operation and Maintenance Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed "Pi" sound is heard once, which means the start of this operation.
  • Page 11: Trouble Shooting

    All manuals and user guides at all-guides.com Trouble shooting The followings are not malfuncition When the air conditoner is started, when the Water flowing sound is heard compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds “...
  • Page 12 All manuals and user guides at all-guides.com Trouble shooting Air does not blow or the fan speed cannot be In DRY mode, when room temperature changed during drying. becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting This happens when the frost accumulated on Water or vapor generated from the outdoor...
  • Page 13: Customer Need-To-Know

    All manuals and user guides at all-guides.com Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
  • Page 14: Instructions To Installation

    All manuals and user guides at all-guides.com Instructions to installation 1. Safety precautions Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, WARNING , those points which are related to the strong possibility of an installation WARNING done in error resulting in death or serious injury are listed in the section.
  • Page 15 All manuals and user guides at all-guides.com Instructions to installation PRECAUTION Execute proper grounding. Do not connect the earth wire to a gas pipe, water pipe, lightening rod, or a telephone ground wire. Improper placement of earth wires can result in electric shock. An electric leakage breaker must be installed, otherwise electric shock or other accidents would occur.
  • Page 16 All manuals and user guides at all-guides.com Instructions to installation 4. Choose the installation place Install the indoor unit where the weight of the unit can be supported. Install the indoor unit where the heat source and steam source are not close and the unit inlet and outlet are not blocked.
  • Page 17 All manuals and user guides at all-guides.com Instructions to installation (1) Insert the drain hose into the dent of heat insulation materials of indoor unit. (2) Insert the indoor/outdoor electric cord from backside of indoorunit, and pull it out on the front side, then connect them.
  • Page 18 All manuals and user guides at all-guides.com Instructions to installation (3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end. (4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver. Fig.1 A.
  • Page 19: When Trouble Happens

    All manuals and user guides at all-guides.com When trouble happens Insufficient cooling or heating The operation controller Air filter too dirty ? Horizontal swing louver adjusted as required upward ? (in HEAT mode) Any obstacle exists at the air Door or window left opened ? inlet or outlet? Insufficient cooling Too crowed in the room ?
  • Page 20: Failure Code

    All manuals and user guides at all-guides.com Failure code Resumable failures are marked with " ", the others are not resumable failures. Resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds. But the other failure code will disappear only after the unit starts up once again.
  • Page 21 All manuals and user guides at all-guides.com HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P.R.China Web Site: http://www.haier.com...

This manual is also suitable for:

As092xceaaAs122xceaaAs142xceaa

Table of Contents