6. Alignments

Index of this chapter:
6.1 General Alignment Conditions
6.2 Hardware Alignments
6.3 Software Alignments
6.4 White Point Alignments
General Alignment Conditions
6.1
Perform all electrical adjustments under the following
conditions:
Power supply voltage: 90 - 264 V
Connect the set to the mains via an isolation transformer
with low internal resistance.
Allow the set to warm up for approximately 15 minutes.
Measure voltages and waveforms in relation to correct
ground (e.g. measure audio signals in relation to
AUDIO_GND).
Caution: It is not allowed to use heat sinks as ground.
Test probe: R
> 10 M, C
i
Hardware Alignments
6.2
Not applicable.
Software Alignments
6.3
Not applicable.
White Point Alignments
6.4
Steps for white point alignment are listed below
Run the PC
Connect the USB cable of DB07 board.
Run the video pattern generator, adjust %80 white pattern.
Run the color Analyzer CA210, make the CAL the probe.
Calibration steps
Select the CAL position on the probe.
Press button 0-CAL.
Wait 5 seconds.
Select MEAS position on the probe.
Wait a minimum of 15 mins, avg. time is 45 mins.
Connect the scart cable to TV.
Value
X
0.274+/-(0.008)
Y
0.280+/-(0.008)
If you don't have a colour analyser, you can use the default
values. This is the next best solution.
, 50/ 60  3 Hz.
AC
< 20 pF.
i
COOL
NORMAL
0.287+/-(0.008)
0.295+/-(0.008)
Alignments
VEM14.1E_LA
Place the probe across the display (center position, 0.5 cm
at 90 degrees.
Check the PC, select the COM port.
Select the model type OEM.dat.
Press the START button.
Wait for the software to set all modes (normal, cool, warm)
Wait for the OK-READY sign.
If you don't have a colour analyser, you can use the default
values. This is the next best solution.
White Point Alignments
6.5
If you don't have a colour analyser, you can use the default
values. This is the next best solution.
Run the PC
Connect the USB cable of DB07 board.
Run the video pattern generator, adjust %80 white pattern.
Run the color Analyzer CA210, make the CAL the probe.
Calibration steps
Select the CAL position on the probe.
Press button 0-CAL.
Wait 5 seconds.
Select MEAS position on the probe.
Wait a minimum of 15 mins, avg. time is 45 mins.
Connect the scart cable to TV.
Place the probe across the display (center position, 0.5 cm
at 90 degrees.
Check the PC, select the COM port.
Select the model type OEM.dat.
Press the START button.
Wait for the software to set all modes (normal, cool, warm)
Wait for the OK-READY sign.
Table 6-1 Default White Point Alignment Values
WARM
0.313+/-(0.008)
0.329+/-(0.008)
back to
div. table
6.
EN 19
2014-Apr-09