10. WIRING ALL READY-TO-RUN (RTR) MODELS

Ready-To-Run models include a circulator with built-in priority zoning relay. The aquastat is pre-wired and controls the
circulator. Line voltage must be supplied and a signal wire must be run to fire the boiler.
To wire RTR models, select the appropriate diagram from the following pages. If a suitable diagram is not available for your
application, please contact AMTROL Tech Support at (401)535-1216. Always disconnect power before wiring the unit. Ensure
that the proper conduit and connections are used per your local code. In lieu of local code, the National Electric Code should
be followed.
Indirect
Aquastat
HONEYWELL L8148A OR SIMILAR W/120V HIGH LIMIT
1
2
3
4
DHW AQUASTAT
FACTORY WIRED
DRY CONTACT
TO BOILER OR
EXTERNAL RELAY
CIRCULATOR RELAY OPERATION
CIRCULATOR RELAY BOX
1
2
3
4
-23-
PR
PR
IN
OUT
LIVE NEUT
LINE IN
LINE OUT
CANCELS ON
CALL FOR DHW
PR
PR
IN
OUT
LIVE NEUT
L2
L1
L1
L2
T
T
HIGH
LIMIT
INPUT
C1
C2