Note: When you secure the top cap, if the top edges of the shrouds do not fit securely into the
slot between its lip and ribs, remove the cap and the shrouds. Loosen the fasteners securing
each of the shroud clips, then secure each clip again so that it is mounted as high on the weight
stack frame as possible. You will need to push the clips up and hold them in place while you
secure them. After you have repositioned all of the shroud clips, repeat this procedure to install
the shrouds and the top cap.
Bolt equipment to floor
Precor recommends that the strength equipment be bolted down at all anchoring
points. Bolting is made possible through the bolt holes on each foot. The inside
diameter of each hole is 14.3 mm.
NOTE As floor materials vary, it is important to consult a licensed
contractor to advise on proper bolting techniques and appropriate
fastener types.
CAUTION Standards can change. Precor recommends you keep apprised of
your local industry standards. Precor shall not be held liable for failure to
properly bolt the strength equipment to the floor.
Apply labels
1. Attach the Instructional label to the inside shroud under the top cap. The label should be
aligned with the left and right edge of the tray on the top cap. There are small marks on the
lower lip of the top cap to indicate the proper label position.
Verify operation of equipment
Once assembly is complete, verify safe operation by checking the following points:
Cable tension is correct and the cable is moving smoothly on its pulleys.
l
Movement arm is stable and moves smoothly through its range of motion.
l
Adjustment points are stable and move smoothly through their range of motion.
l
Figure 19
Disassemble the equipment
You may occasionally need to disassemble this unit to move it between rooms or buildings. In such
cases, reverse the assembly steps in this manual to disassemble. After the unit has been moved, fol-
low the steps in this manual to reassemble it.
WARNING: You will need assistance to disassemble this unit. The weight tower can become
unstable during parts when disassembling. Make sure the weight tower is supported safely
throughout the process and NEVER attempt to disassemble by yourself.

Maintenance information

It is important that the equipment be maintained in accordance with the Vitality Selectorized Line