4. Insert one end of the Anode Support into the anode button,
then the other as shown in Fig. 3-5.
Support
CRT
5.
Confirm that the Support is securely connected.
6.
Put the Rubber Cap on without moving any parts.
4. REMOVAL OF DEFLECTION YOKE
(Refer to Fig. 4-1)
Loosen the screw 1.
1.
2.
Remove the Convergence • Purity Magnet in the
direction of arrow (A).
Loosen the screw 2.
3.
4.
Remove the 3 Wedges.
5.
Remove the Deflection Yoke in the direction of arrow
(B).
Wedge
Deflection Yoke
Wedge
INSTALLATION
Install new Deflection Yoke in reverse steps of REMOVAL.
NOTE
After adjusting the purity and the convergence, tighten the
screw 2 and lock the wedges. See page 2-31 for Purity Adj.
CM152
DISASSEMBLY INSTRUCTIONS
Fig. 3-5
2
1
(B)
(A)
Convergence •
Purity Magnet
Fig. 4-1
2-11