DESCRIPTION
10STRIKERE34
¾" Strike
(10STRIKEREV34)
UL294 & UL1034 REQUIREMENTS
‰ Indoor use only.
‰ Wiring methods shall be in accordance with NFPA70.
‰ 10STRIKEREV is intended to be used with UL-listed, rim type, fire exit hardware, Von Duprin LLC, Model 99-F.
‰ 10STRIKEREV shall not installed in the fail-secure mode unless permitted by the local Authority Having Jurisdiction (AHJ), and shall not impair panic hardware
operation.
‰ Remove the "Listed Fire Rated Hardware" label if the 10STRIKEREV is used in the fail-safe operation. Using these strikes in fail-safe operation negates the
fire rating. 10STRIKEREV is fire rated in fail-secure operation only.
‰ 10STRIKEREV are access control unit accessories intended to be controlled by an access contol system. The purpose of access control systems is to provide a
means for controlling lock and unlocking external and internal doors of a premise.
GENERAL SAFETY
‰ Shut off all power going to electrical encolsure before attempting any wiring procedures.
!
‰ Maintain a clean and safe environment when working in public areas.
‰ Constantly be aware of pedestrian traffic around the door area.
‰ Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
CAUTION
‰ ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board,
ensure you dissipate your body's ESD charge.
‰ Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
‰ Ensure compliance with all applicable safety standards (i.e. ANSI A156.31) upon completion of installation.
‰ DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA,
Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
©BEA
| Original Instructions
75.5012.02 RIM EXIT ELECTRIC STRIKE 20211109
½" Strike
10STRIKERE34
(10STRIKEREV12)
RIM-EXIT ELECTRIC STRIKE
Rim-exit electric strike for access doors
with ½" and ¾" housing thickness
TECHNICAL SPECIFICATIONS
Operating voltage
12 or 24 VDC
Current draw
540mA (12 VDC)
270mA (24 VDC)
Operating temperature
14 – 120 °F (-10 – 49 °C)
Humidity
0 – 85% non-condensing
Static strength
1500 lbs (680kg)
Dynamic strength
70 ft-lbs
Endurance
250,000 cycles (UL-tested)
1,000,000 cycles (factory-tested)
Lock mode
field selectable fail-safe or fail-secure
Performance level
destructive attack: level I
line security: level I
standby power: level I
endurance: level IV
Material (strike body)
brushed stainless steel (US32D)
Frame application
metal / wood
Latch throw
¾" or ½"
(housing thickness)
Specifications are subject to change without prior notice.
All values measured in specific conditions.
Page 1 of 2

Advertisement

loading

Summary of Contents for BEA 10STRIKEREV34

  • Page 1 ‰ Ensure compliance with all applicable safety standards (i.e. ANSI A156.31) upon completion of installation. ‰ DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair: 1.
  • Page 2 BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.