Page 12
本 社:〒140-0014 東京都品川区大井4-4-4 TEL 03(3775)1521(代) FAX 03(3775)1732 大 阪 営 業 所:〒550-0013 大阪市西区新町2-18-19 TEL 06(6532)4488(代) FAX 06(6538)265 名古屋 営業所:〒480-1162 愛知県長久手市段の上2202-301 TEL 0561(76)0422(代) FAX 0561(76)0423 URL:http://www.bestool-kanon.co.jp...
Page 13
Operation Manual for Digital Torque Wrench DTC-REV Series Standard Device Type ◆Applicable Device Type◆ DTC-N10REV DTC-100REV DTC-N50REV DTC-500REV DTC-N100REV DTC-1000REV DTC-N200REV DTC-2000REV DTC-N300REV DTC-3000REV DTC-N500REV DTC-5000REV DTC-N1000REV DTC-10000REV Nakamura MFG., Co. Ltd.
Page 15
INDEX Introduction Safe Operation P.3 Warning! Caution! Main Functions Specifications P.4 Overview of Parts and their Functions How to use DTC-REV P.5 Function Setting P.6- P.7 Details of Measurement Mode Details of Preset Mode P.7 Details of other Setting Bar Display Mode P.8...
Page 16
Introduction Thank you very much for purchasing your DTC-REV series digital torque wrench. Please read this operation manual carefully before using it, in order to understand your new wrench’s functions. Keep this manual in a safe place for future reference. Safe Operation Read the following instructions carefully before using your torque wrench, and be sure to observe them.
Page 17
Main Functions ● You can check measurement of tightening torque (CW) and loosening torque (CCW) with digital display. ● When the graph mode is used, a bar graph is displayed corresponding to the torque allowing you to control values visually. ●...
Page 18
How to Use DTC-REV Let's turn on power. Press and hold the power mark key until the message appears. BESTOOL-KANON FUNC Welcome!V.01.00 In several seconds, the following initial screen appears and DTC-REV is now ready for use. The example shows the case that the battery capacity is sufficient, the mode is RUN, 6 data are stored in the memory and the torque value is 0.0.
Page 19
Function Setting To DTC-REV, various function settings are equipped. Set functions according to the purpose of use. Every time SET key is pressed, the screen changes. If you press FUNC key, you can go back to the initial screen anytime. Initial Screen R006 Press FUNC briefly.
Page 20
③ PB Measurement Mode (Peak Hold) The peak torque value is always held. If any peak higher than the held value is entered, the value is renewed. The held value can be reset using CLR key. Setting of preset and tolerance is unavailable. MODE HOLD Effective for measurement in which peaks change continuously.
Page 21
Bar Display Mode Visual tightening (measuring) work can be performed in any of RUN, PA and PB modes. The bar graph displays the load in stages in proportion to the torque. When the preset value and the buzzer are set, the target torque control becomes easier with the aid of sight and sound. To reset the display, press CLR key.
Page 22
Data View Mode The stored data is controlled by the following flow. Use it according to the purpose. Detailed Flow of Data View Mode Initial Screen R006 Press and Hold MODE Torque Mode Data View 100.0 100.0 97.0-103.0 MODE Torque Torque Torque 20.0...
Page 23
Charging ● For charging, always use the product’s own charger. If a different charger is used, failure of equipment, fire or electric shock may be caused. ● Charge the device in an environment that can be monitored. If you find any malfunction such as heat generation or abnormal smell, immediately stop using the device and contact your distributor or us.
Page 24
Head Office: 4-4, Ohi 4-Chome, Shinagawa-ku, Tokyo,140-0014 TEL +81-3-3775-1527 FAX +81-3-3775-1732 URL:http://www.bestool-kanon.co.jp E-mail:oversea@bestool-kanon.co.jp...