INSTALLATION INSTRUCTIONS

CONNECTING TO THE MAINS TERMINAL

Warning: This appliance must be earthed.
·
We recommend you use a new length of 6mm
twin core and earthed cable to ensure your
safety.
·
Make connection as shown in Fig. 12 by
proceeding as follows:-
·
Preform wires to the appropriate shape to suit
fitting into the mains terminal block.
·
Strip
inner
insulation
wirestrippers.
·
Twist the bared wires using pliers.
·
Cut bared wires 10mm away from the end of the
inner insulation. Where uninsulated Earth wires
are used ensure they are suitably sheathed to
leave 10mm bare wire fit into the terminal.
·
Clamp bare wires into the relevant terminal and
check they are held by tugging each one in turn.
·
Clamp the mains cable securely ensuring 5mm of
the outer insulation is inside the terminal block
and that the wires are not taught but not so slack
as to cause any fouling. See Fig. 12.
·
Connect the remaining end of the mains cable to
the cooker point / junction box.
·
Please fuse / miniature circuit breaker in circuit
and switch on at mains.
2
on
wires
using
40
Fig.12