Safety Device; Troubleshooting - DeLonghi TRD40615EBKCA Instructions For Use Manual

Electric oil filled radiator
Table of Contents

Advertisement

Available languages

Available languages

is too high, the heating power will
progressively
be reduced. The display shows
temperature is lowered. To help eliminate
the cause of this alarm, check that the
unit is not covered or obstructed.

SAFETY DEVICE

A safety device switches the appliance off in the event of
overheating. To restart the appliance, contact the De'Longhi
toll free number.
MAINTENANCE AND SERVICE
Always remove the plug from the power outlet and allow the
appliance to cool. Wipe appliance with a soft damp cloth, do
not use detergents and abrasives.
Should the appliance not be in use over a certain length of
time, wrap the cord around the cord holder and store it in a
dry place. This appliance has been built to give many years of
trouble free service. In case of malfunction or doubt, do not
try to repair the appliance by yourself: this may result in a
fire hazard or electric shock. Contact the De'Longhi toll free
number.

TROUBLESHOOTING

PROBLEM
The appliance doesn't work
Probe failure,
the display
shows: PF
The display shows: Ht (High
temperature)
and
automatically
intermittently till the internal
Be sure it is plugged in and that the
electrical outlet is working.
Check for any obstruction.
The temperature may be set too low.
The unit is covered or obstructed.
CAUSE
14
SOLUTION
Plug into the power outlet.
Remove the obstruction and let the
appliance cool down. If the appliance
doesn't work please contact the De'Longhi
toll free number.
Set the temperature to a higher position.
Contact the De'Longhi toll free number.
Check that the unit is not covered or
obstructed. When the product's internal
temperature decreases the alarm will
disappear.