Download Print this page
Robertshaw Uni-Kit 720-079 Installation Data

Robertshaw Uni-Kit 720-079 Installation Data

Universal electronic ignition gas valve

Advertisement

Quick Links

INTERMITTENT PILOT • HOT SURFACE • DIRECT SPARK
The Robertshaw® 720-079 Universal Electronic Ignition Gas Valve
Uni-Kit® is de signed to work equally well on Intermittent Pilot, Direct
spark and Hot Surface applications.
The 720-079 features a manual selector, wiring connections and ad-
justments that are all easily accessible on the top of the valve. The
720-079 Uni-Kit has a pressure regulator that is pre-set at 3.5" W.C.
for natural gas. For L.P. gas applications the valve can be converted by
using a pressure regulator conversion kit that is included.
The 720-079 incorporates a manual valve, pilot valve (dual automatic
valves and a main gas pressure regulator all in a small compact valve
with a swing radius of 3-9/16''. The small size of the 720-079 lends
itself to replacing many O.E.M. and competitive valves. The 720-079
is multi-positional and can be mounted in any position, except upside
down.
APPLICATION LIMITATIONS
Do not use on direct spark or hot surface applications if original valve
was a "slow opening" type. Also 720-079 will not replace Robertshaw
7000K series or White-Rodgers "cycle pilot" gas valves.
SPECIFICATIONS
Electrical Ratings
Pressure Regulator
Natural Gas
L.P. gas
Ambient Temperature
Maximum Inlet Pressure
REGULATION CAPACITIES
NATURAL
SIZE
MIN.
3/8" x 3/8"
15,000
1/2" x 3/8"
15,000
1/2" x 1/2"
15,000
1/2" x 3/4"
15,000
3/4" x 3/4"
15,000
INSTALLATION INSTRUCTIONS - ALL APPLICATIONS
Turn off gas supply and electrical power to equipment before servicing.
CAUTION
THIS DEVICE SHOULD BE INSTALLED BY A QUALIFIED
TECH NICIAN WITH DUE REGARD FOR SAFETY AS IMPROPER
IN STALLATION COULD RESULT IN A HAZARDOUS CONDITION.
PIPING
1. Check replacement valve for multiple outlets (side outlets). If it has
them, be sure all unused outlets are plugged using the socket plugs
provided.
2. Pipe or tubing must be clean and free of scale and dirt.
3. Make sure gas piping is pressure tested before control is connected.
High pressure can damage control causing a hazardous condition. Do
not subject control to more than 1/2 PSI, (14" W.C.) inlet pressure.
24 VAC, .45 amps
factory set at 3.5" W.C.
factory set at 11.0" W.C.
-40° to 175°F
7" W.C. - natural gas
14" W.C. - L.P. gas
TYPE GAS
L.P.
MAX.
MIN.
MAX.
175,000
15,000
280,000
175,000
15,000
280,000
200,000
15,000
320,000
200,000
15,000
320,000
200,000
15,000
320,000
INSTALLATION DATA
720-079 UNIVERSAL ELECTRONIC
IGNITION GAS VALVE UNI-KIT
* A plug is included for hot surface and direct spark applications.
NOTE:
To prevent unsafe attempts at repair, special screws are used and replacement
parts are NOT available.
4. If it's not already installed, a drip leg (sediment trap) must be added to
the gas supply line to the control. (See figure below.) All piping must
comply with local codes and ordinances and with National Fuel Gas Code
(ANSI Z223.1/ NFPA, No. 54).
1
®

Advertisement

loading

Summary of Contents for Robertshaw Uni-Kit 720-079

  • Page 1 APPLICATION LIMITATIONS Do not use on direct spark or hot surface applications if original valve was a “slow opening” type. Also 720-079 will not replace Robertshaw 7000K series or White-Rodgers “cycle pilot” gas valves. SPECIFICATIONS Electrical Ratings 24 VAC, .45 amps...
  • Page 2 1. Check the system for the proper transformer by comparing the VA unit to the ”C” terminal on the gas valve. ratings of the transformer and the system. The system rating is determined by multiplying the voltage draw times the amp draw. Normally 20VA TYPICAL ROBERTSHAW INTERMITTENT PILOT APPLICATION...
  • Page 3 1. Check the system for the proper transformer by comparing the VA ratings of the transformer and the system. The system rating is deter- mined by multiplying the voltage draw times the amp draw. TYPICAL ROBERTSHAW HOT SURFACE APPLICATION...
  • Page 4 20VA transformers are sufficient for heating only applica tions and 40VA for heating/cooling applications. NOTE: Improper transformer VA rating will cause erratic system operation. 2. Locate the white wire terminal adaptor (jumper) that is included with the 720-079 gas valve. TYPICAL ROBERTSHAW DIRECT SPARK APPLICATION...
  • Page 5 OPERATING INSTRUCTIONS 1. Turn wall thermostat to its lowest setting. Remove burner access CAUTION panel(s). 1. WARNING: If you do not follow these instructions exactly, a fire Selector arm must only be operated by hand (see below). DO NOT or explosion may result with property damage, per sonal injury use pliers, wrenches or other tools to operate the arm.
  • Page 6 Robertshaw®, Ranco®, Paragon® and Uni-Line® are www.uni-line.com For Technical Service trademarks of Robertshaw, its subsidiaries and/or www.robertshaw.com Customer Service Telephone 1.800.304.6563 Telephone 1.800.445.8299 affiliated companies. All other brands mentioned ©2014 Robertshaw Customer Service Facsimile 1.800.426.0804 Facsimile 1.630.260.7294 HVACCustomerService@robertshaw.com TechnicalService@robertshaw.com may be the trademarks of their respective owners.