AIR COMPRESSOR – OIL LUBRICATED
OPERATING INSTRUCTIONS
PLEASE READ THIS MANUAL BEFORE INSTALLING OR USING YOUR AIR
COMPRESSOR UNIT. IT CONTAINS VALUABLE INFORMATION THAT WILL HELP
YOU IN THE RECEIVING, INSTALLATION, USE, AND MAINTENANCE OF THE UNIT.
KEEP THIS BOOKLET IN A SAFE PLACE FOR FUTURE REFERENCE.
COMPRESSOR IDENTIFICATION
Please fi ll in the appropriate information in the spaces provided below. These numbers will allow us to correctly
identify your compressor in the event you need service or parts.
UNIT MODEL NUMBER: _____________________________________________________________ (i.e. TK-5080V)
(Located on Base of Air Receiver or Air Receiver – White Label)
UNIT SERIAL (MFG.) NUMBER: ________________________________________________________ (i.e. OC-4963)
(Located on Base of Air Receiver or Air Receiver – White Label)
PUMP MODEL NUMBER: ________________________________________________________________ (i.e. TK-50)
(Located on Front or Side of Compressor Pump)
PUMP SERIAL NUMBER: _______________________________________________________________ (i.e. 23045)
(Located on Front or Side of Compressor Pump – Professional Series Compressor Pumps do not have
Serial Numbers)
ELECTRICS: ___________________________________________________________________ (i.e. 230V/60Hz/1PH)
(Located on Nameplate of Motor)
COMPRESSOR DISTRIBUTOR ______________________________________________________________________
(Who You Bought the Air Compressor From)
63 Morrow Road, Barrie, Ontario, Canada L4N 3V7 Phone: 1-800-668-8448 Fax: (705) 721-8646 www.omegacompressors.com

Advertisement

loading

Summary of Contents for Omega TK-5080V

  • Page 1 Please fi ll in the appropriate information in the spaces provided below. These numbers will allow us to correctly identify your compressor in the event you need service or parts. UNIT MODEL NUMBER: _____________________________________________________________ (i.e. TK-5080V) (Located on Base of Air Receiver or Air Receiver – White Label) UNIT SERIAL (MFG.) NUMBER: ________________________________________________________ (i.e.
  • Page 2: Table Of Contents

    For us, it’s not just business. It’s personal. TABLE OF CONTENTS • COMPRESSOR IDENTIFICATION ............Front Cover • TABLE OF CONTENTS ............... Inside Front Cover • SAFETY PRECAUTIONS ..............pg. 1 • GENERAL DESCRIPTION OF AIR COMPRESSOR ....... pg. 1 •...
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Please familiarize yourself with the following information for preventing damage to your air compressor unit and injury to the operator and/or property damage. ELECTRICAL HAZARD Never use the air compressor without connection to a properly grounded outlet with the specifi ed voltage and fuse protection.
  • Page 4: Inspection Of Air Compressor

    GENERAL REQUIREMENTS As the owner of a new Omega Air Compressor Unit, it is your responsibility to ensure it is installed correctly, as well as maintained and serviced on a regular basis. Information has been included in this booklet outlining the suggested air compressor maintenance schedules and a trouble shooting guide.
  • Page 5: Compressor Lubrication

    Omega Compressors or Motor manufacturer’s warranty. The warranty that exists on the electric motor is that of the original manufacturer. In the event of a motor failure contact your Omega Distributor or Service Centre for the location of the nearest authorized motor service centre.
  • Page 6: Preventative Maintenance

    INITIAL START-UP PROCEDURE Do not attempt to operate the unit without fi rst checking whether there is oil in the pump. Add oil as required. Serious damage may result from use without oil. See page for proper compressor lubrication. Check to see that nuts and bolts are all snug. This must be done, as some fasteners may become loose in transit. Check to see if the belt is installed properly, with proper tension.
  • Page 7 TROUBLE SHOOTING GUIDE CONDITION CAUSE CORRECTIVE ACTION Compressor Will Not Start 1. Fuse blown or circuit 1. Check for cause of blown fuse or breaker breaker tripped. and replace or reset. 2. Loose electrical connections. 2. Check wiring connections. 3. Overheated motor. 3.
  • Page 8 3. Pump valves or tank check 3. Clean, repair or replace. valve leaking, sticking or 4. Fix leaks. carbon build up 5. Contact Omega Compressor distributor. 4. Air leaks in the system. 5. Undersized unit for air requirements. Compressor Over-Heating 1.
  • Page 9 Seized Compressor Pump. 1. Started without oil. Pump will require an overhaul. Flywheel Will Not Turn 2. Ran low on oil. Contact Omega Compressor Service Centre. Freely. 3. Worn rod bearing inserts. 4. Piston and pin assembly seized. 5. Worn crankshaft bearings.
  • Page 10 MAINTENANCE LOG CHART Maintenance carried out must be registered here below. Please refer to page 4 for proper Preventative Maintenance Procedures...
  • Page 11 MAINTENANCE LOG CHART...
  • Page 12 Compressed Air Accessories Aluminum Air Piping Magnetic Starters Ball Valves Oil Monitors Check Valves Oil/Water Separators Compressed Air Filters Pilot Valves Compressor Oil Pneumatic Auto Drains Compressor Pumps Pressure Switches Desiccant Air Dryers Refrigerated Air Dryers Electric Motors Remote Air Receivers Electronic Auto Drains Safety Valves Filter Elements...

This manual is also suitable for: