Partition Plate / Sound Insulations - Daikin 18000 Btu Service Manual

Removal procedure

Advertisement

Si002155E

5. Partition Plate / Sound Insulations

Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1. Remove the partition
plate.
1
Detach the snap band
of compressor harness.
2
Remove the 3 screws,
and then the partition
plate.
2. Remove the sound
insulations.
1
Remove the sound
insulation (top).
2
Remove the sound
insulation (outer).
Removal Procedure
disassembling work.
Procedure
Snap band
Partition plate
Sound insulation (outer)
(R26211)
Sound insulation (top)
(R26213)
(R26214)
Partition Plate / Sound Insulations
Points
 When reassembling, fit the
hook into the bottom frame.
Hook
Bottom frame
 Since the piping ports are
torn easily, remove the
sound insulation carefully.
(R26212)