Domestic Hot Water Control; About Domestic Hot Water Control - Daikin Altherma 3 R ECH2O User Reference Manual

Hide thumbs Also See for Altherma 3 R ECH2O:
Table of Contents

Advertisement

5
|
Operation

5.7 Domestic hot water control

5.7.1 About domestic hot water control

User reference guide
30
2 Adjust the desired leaving water temperature.
a
2
35
°C
Main zone
a
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
If scheduling is on after changing the desired leaving water temperature
The temperature will stay the same as long as there is no scheduled action.
The desired leaving water temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off scheduling.
To turn off leaving water temperature scheduling
1 Go to one of the following:
[2.1]: Main zone > Schedule
[3.1]: Additional zone > Schedule
2 Select No.
To enable weather-dependent operation for the leaving water temperature
See
"5.9.4 Using weather-dependent
Depending on the DHW tank mode (installer setting), you use a different domestic
hot water control:
Reheat only
Scheduled reheat
INFORMATION
In case of error code AH and no interruption of the disinfection function occurred
due to domestic hot water tapping, following actions are recommended:
It is recommended to program the start-up of the disinfection function at least
4 hours later than the last expected large hot water tapping. This start-up can be
set by installer settings (disinfection function).
b
+
b
+
4
curves" [
 45].
EBSH/X(B)11+16P30+50DF
Daikin Altherma 3 R ECH₂O
4P663484-1 – 2021.07