11.7 Leakage Checkpoints

Figure 11
Checkpoint
Description
A
Condensation may be seen on pipes in humid weather or pipe connections may be leaking.*
B
The primary anode rod may be leaking.
C
Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area.
D
The temperature-pressure relief valve may be leaking at the tank fi tting.*
The elements may be leaking at the tank fi tting. Turn electrical power"OFF", remove access panels and insulation block and pad. If leaking is visible around element,
E
follow proper draining instructions and remove element. Reposition or replace gasket on element. Place element into opening and tighten securely. Then follow
"Filling the Water Heater" instructions in the "Installation Instructions" section.
F
Water from drain valve may be due to the valve being opened slightly.
G
The drain valve may be leaking from the tank fi tting.*
Water in the water heater bottom or on the fl oor may be from condensation, loose connections or the temperature-pressure relief valve. DO NOT replace the water
H
heater until full inspections of all possible water sources are determined and necessary corrective steps have been taken.*
Table 5
* To check where threaded portion enters tank, insert cotton swab between jacket
opening and fi tting. If cotton is wet, follow "Draining" instructions in the "Service
and Adjustment" section and then remove fi tting. Put pipe dope or Tefl on tape on
the threads and replace. Then follow "Filling the Water Heater" instructions in the
"Installation Instructions" section.