Fujitsu M4097D Installation Procedures
Fujitsu M4097D Installation Procedures

Fujitsu M4097D Installation Procedures

Scsi scanner with vrs (gsa-1) for windows 2000 / xp
Hide thumbs Also See for M4097D:

Advertisement

Quick Links

Fujitsu SCSI
Scanner Installation Procedures with
If you are installing the following model scanners with the Kofax 850S or 1700S
Adrenaline SCSI controller and a GSA-1 scanner interface card then use this document.
M4097D-VRS
Hardware requirements.
1. You will need a PC system that meets both Fujitsu's and Kofax's
recommended specifications
2. Kofax 850S/1700S Adrenaline controller for the M4097D/M4099D respectively.
3. Six foot (maximum) Wide SCSI 68-pin to 68-pin cable.
For recommended PC system specifications and SCSI controllers please
reference the
Scanner Hardware Reference
Operating System Disk.
Step A: Installing the VRS drivers.
First boot your PC and install the Kofax VRS drivers that shipped with the scanner.
The installation includes the adrenaline hardware runtime drivers. The drivers can be
down loaded from the following link
Special note: When installing the VRS drivers and any other software that contains
Kofax's Image Controls pay close attention to the individual runtimes. It is strongly
recommended that you install the oldest/lower runtime application first.
Step B: Installing the Adrenaline 850S/1700S Adrenaline controller
1. Shut down your PC and remove the case cover.
2. Locate a free PCI slot and remove the back plate if necessary.
3. Install the SCSI controller in an open PCI slot. Make sure that the card is
seated completely in the slot and secured in the frame.
Warning! Failure to secure the SCSI controller in the PC can result in damage
to the SCSI card, scanner, and/or your system.
4. Boot your PC without the scanner attached and check for errors.
Step C: Unlocking the shipping lock.
If your model scanner does not have a flatbed then proceed to Step D.
The flatbed model scanners typically include a lock on the flatbed designed to
protect the scanner during shipment. Before the scanner can be used the
shipping lock must be unlocked. To unlock it do the following:
Rev010807L
Windows 2000 / XP
M4099D-VRS
Drivers and
VRS (GSA-1)
page. You may also need your
Downloads.
Page 1 of 3

Advertisement

loading

Summary of Contents for Fujitsu M4097D

  • Page 1 Adrenaline SCSI controller and a GSA-1 scanner interface card then use this document. M4097D-VRS M4099D-VRS Hardware requirements. 1. You will need a PC system that meets both Fujitsu’s and Kofax’s recommended specifications 2. Kofax 850S/1700S Adrenaline controller for the M4097D/M4099D respectively. 3. Six foot (maximum) Wide SCSI 68-pin to 68-pin cable.
  • Page 2 SCSI cable to the scanner or workstation. Failure to follow the procedure above could result in damage to the SCSI card, scanner, and/or your system. Termination and the SCSI ID’s for both the M4097D and M4099D VRS scanners are handled automatically. Connect the SCSI cable to the Kofax controller and to the Wide SCSI (68-pin) port on the scanner.
  • Page 3 Step F: Installing third party software applications. After you have successfully installed all the Fujitsu software and hardware, then it is time to install any additional third party scanning software that you wish to use. Please follow the software manufacturer’s instructions for installation. Remember when installing any software that contains Kofax’s Image Controls pay close attention to the...