IC2 VHiLC78641E-1: Servo/Signal Control (LC78641E) (2/2)
Terminal Name Input/Output Setting in Reset
Pin No.
44
LVDD
45
LCHO
46
LVSS
47
RVSS
48
RCHO
49
RVDD
50
XVDD
51
XIN
52
XOUT
53
XVSS
54
ASLRCK
55
ASDACK
56
ASDFIN
57*
LRSY
58*
DATACK
59*
DATA
60*
16M
61*
SFSY
62*
SBSY
63*
PW
64
SBCK
65
CE
66
CL
67
DI
68
DO
69
INT
70
WRQ
71
RES
72
DRF
73
VDD5V
74
VSS
75
CONT6
Input/Output
76
CONT7
Input/Output
77*
V/P
78*
FSEQ
79
DEFECT
Input/Output
80*
EFMO
In this unit, the terminal with asterisk mark (*) is open terminal which is not connected to the outside.
Be sure to supply the same potential to each power terminal. (VVDD, ADAVDD, VDD, LVDD, RVDD, XVDD)
Terminal witch is controlled by the power terminal (VDD5 V) for a microcomputer interface :
CE (65 pin), CL (66 pin), DI (67 pin), DO (68 pin), INT (69 pin), WRQ (70 pin), RES (71 pin), DRF (72 pin),
CONT6 (75 pin), CONT7 (76 pin)
All manuals and user guides at all-guides.com
Input
L channel
Output
1/2VDD
D/A converter L channel output terminal.
R channel
Output
1/2VDD
D/A converter R channel output terminal.
Input
Input
For quartz
Input
Oscillation
oscillation
Output
Oscillation
Input
For anti
Input
shock mode
Input
Output
L
For digital
Output
L
data output
Output
L
Output
Clock output
16.9344 MHz output terminal.
Output
L
Output terminal of synchronous signal of subcode frame.
It drops when subcode stand by.
Output
L
Output terminal of synchronous signal of subcode block.
Output
L
Output terminal of sub codes P,A,R,S,T,U and W.
Input
Clock input terminal to read sub code. (When not used, connect to 0 V)
Input
Input
microcomputer
Input
interface
Output
L
Output
H
Output
H
Input
Reset input terminal of LC78640. When turning on power, set it at "L".
Output
L
Focus ON detection terminal.
Input
Power terminal for microcomputer interface.
Ground terminal of digital system. Surely connected to 0 V.
Input mode
General purpose input/output terminal 6.
Input mode
General purpose input/output terminal 7.
Output
H
Monitor output terminal for automatic switch of rough servo/phase control.
"H" for rough servo, and "L" for phase servo.
Output
L
Output terminal synchronous signal detection. "H" is output when
synchronous signal detected by EFM signal matches synchronous signal
internally generated.
Input mode
Defect terminal. After resetting, it is configured as an input terminal. It can be
controlled from the outside.
It also becomes a defect monitor terminal under command control
Output
Unfixed
EFM signal output terminal.
Function
Power terminal for L channel.
Ground terminal for L channel. Surely connected to 0 V.
Ground terminal for R channel. Surely connected to 0 V.
Power terminal for R channel.
Power terminal for quartz oscillation.
Ground terminal of 16.9344 MHz quartz oscillation.
Ground terminal for quartz oscillation. Surely connected to 0 V.
L/R clock input terminal. (When not used, connect to 0 V)
Bit clock input terminal. (When not used, connect to 0 V)
L/R channel data input terminal. (When not used, connect to 0 V)
L/R clock output terminal.
Bit clock output terminal.
L/R channel data output terminal.
For
Chip enable signal input terminal.
Data transmission clock input terminal.
Data input terminal.
Data output terminal.
Interruption signal output terminal.
Interruption signal output terminal.
– 47 –
CD-BK100W/CD-BP90W
Controlled with serial data command
from microcomputer. When not used,
set it as the input terminal and
open it by connecting to 0 V, or set it
as the output terminal and open it.