[Firmware Update]; [Service Password] - Panasonic PT-RQ35K Operating Instructions Manual

Hide thumbs Also See for PT-RQ35K:
Table of Contents

Advertisement

2)
Press the <ENTER> button.
f The [SECURITY PASSWORD] screen is displayed.
3)
Enter a security password and press the <ENTER> button.
f The [INITIALIZE] screen is displayed.
Press as to select [USER SETTINGS].
4)
5)
Press the <ENTER> button.
f The [USER SETTINGS] screen is displayed.
Press as to select an item.
6)
[OPERATION SETTING]
[REGISTERED SIGNAL]
[NETWORK/E-MAIL]
[LOGO IMAGE]
[UNIFORMITY]
[CONVERGENCE]
[OTHER USER SETTING]
Press qw to switch the setting.
7)
f The items will switch each time you press the button.
[KEEP]
[INITIALIZE]
f Repeat Steps 6) to 7) until the desired initialization items are set.
Press as to select [INITIALIZE].
8)
9)
Press the <ENTER> button.
f The confirmation screen is displayed.
10) Press qw to select [OK], and press the <ENTER> button.
Note
f To return the setting in the [PROJECTOR SETUP] menu → [LIGHT OUTPUT] to the factory default setting, initialize it by selecting [OTHER
USER SETTING].
f To return the setting of [Time Zone] in the [Adjust clock] page of the web control screen and the setting of the [PROJECTOR SETUP] menu
→ [DATE AND TIME] → [TIME ZONE] to the factory default settings, initialize them by one of the following methods.
g Initializing by selecting the [PROJECTOR SETUP] menu → [INITIALIZE] → [FACTORY RESET]
g Initializing by setting the [PROJECTOR SETUP] menu → [INITIALIZE] → [USER SETTINGS] → [OTHER USER SETTING] to
[INITIALIZE]

[FIRMWARE UPDATE]

Rewriting of the firmware is possible by using a USB memory.
For details of operation, refer to "Updating the firmware using the USB memory" (x page 282).

[SERVICE PASSWORD]

This function is used by a service person.
204 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
The [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] and [MAX
LIGHT OUTPUT LEVEL] are initialized.
[LIGHT OUTPUT] is not initialized. The [LIGHT OUTPUT] setting is maintained.
All the signals registered in [SIGNAL LIST] are initialized.
All the setting items under the [NETWORK] menu and all the setting items under the operation page
in the [Detailed set up] page and the Crestron Connected of the web control screen are initialized.
f The items of [Time Zone], [Date], and [Time] in the web control screen are not initialized.
f The information such as the self-signed certificate already created in the [Https set up] page of the
web control screen or the server certificate already installed is not initialized.
Image registered in [USER LOGO] is initialized.
The [DISPLAY OPTION] menu → [UNIFORMITY] is initialized.
The [POSITION] menu → [CONVERGENCE] is initialized.
The user data other than mentioned above are initialized.
Does not return to the factory default settings and maintains the current settings when initialization is
executed by [USER SETTINGS].
Returns to the factory default settings when initialization is executed by [USER SETTINGS].