Fireplace Specifications - Marco Designer Series Installation Instructions Manual

41"
Table of Contents

Advertisement

1 ¹⁄₂"
Figure 8
Figure 9
Step 3. Refer to fireplace drawings and specifi-
cations on pages 6 and 7 for framing dimensions
and details. Frame appliance enclosure as illus-
trated in Figures 11 through 14 on page 8.
IMPORTANT: UNDER NO CIRCUMSTANCES
CAN THE FIREPLACE TOP SPACERS ( FIGURE
10 ) BE REMOVED OR MODIFIED, NOR MAY
YOU NOTCH THE HEADER TO FIT AROUND OR
BE INSTALLED LOWER THAN THE SPACERS.
THE HEADER MAY BE IN DIRECT CONTACT
WITH THE TOP SPACERS BUT MAY NOT BE
SUPPORTED BY THEM.
Note: The framed depth, 23 ⁷⁄₈ " (606 mm) from
a framed wall, must always be measured from
a finished surface. If a wall covering such as
drywall is to be attached to the rear wall, then
the 23 ⁷⁄₈ " (606 mm) must be measured from
the drywall surface. It is important that this
dimension be exact.
If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.
The header may rest on the top metal spacers,
but must not be notched to fit around them.
Consult all local codes.
6

FIREPLACE SPECIFICATIONS

Metal Safety Strips
Blocking
Metal Safety Strips
Gas Line
Access
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
(318 mm)
8 ³⁄₈"
(213 mm)
22 ⁵⁄₁₆"
(566 mm)
(1187 mm)
(1051 mm)
38 ⁷⁄₁₆"
(976 mm)
23 ¹⁄₂"
(597 mm)
Left Side
8 ¹⁄₂"
(216 mm)
12 ¹⁄₂"
(318 mm)
1"
(25 mm)
(1238 mm)
12 ¹⁄₂"
41"
(1041 mm)
2 ⁷⁄₈"
(73 mm)
46 ³⁄₄"
Front
Combustion
Air Inlet
Gas Line
Access
41 ³⁄₈"
17 ⁵⁄₁₆"
13 ⁵⁄₈"
(439 mm)
(346 mm)
22 ⁷⁄₈"
(581 mm)
Right Side
31 ⁹⁄₁₆"
(802 mm)
Fireplace
Top Spacer
46 ³⁄₄"
(1187 mm)
48 ³⁄₄"
Top View
16 ⁵⁄₁₆"
(414 mm)
46 ³⁄₈"
(1178 mm)
7 ³⁄₄"
(197 mm)
Fireplace Top Spacer
9 ⁷⁄₈"
(251 mm)
46 ³⁄₈"
(1178 mm)
10"
(254 mm)
Junction
Box
23 ¹⁄₂"
(597 mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D41cfD41hcD41tcfD41thcD41cfiD41hci ... Show all