Technical Repair Guide; Adjusting To Specific Room Conditions - Emerson White-Rodgers MCS600W Owner's Manual

Media air cleaner, electronic air cleaner
Table of Contents

Advertisement

Available languages

Available languages

Technical Repair Guide

Technical Repair Guide
WARNING: RISK OF ELECTRIC SHOCK
These servicing instructions are for use by qualified personnel
only. To reduce the risk of electric shock, do not perform any
servicing other than that contained in the operating instructions
unless you are qualified to do so.
This guide contains service checks to assist service personnel
in locating and correcting any condition that might occur to
render the air cleaner ineffective or inoperative. The air cleaner
has been designed with replaceable components, such as the
high voltage power supply which allows the service person to
simply replace a component rather than attempt repair of
components in the field.
8
ADJUSTING TO SPECIFIC ROOM
CONDITIONS
Program Setting 1: Service Indicator
The Service Indicator is used to predict when the filter will need
cleaning (electronic air cleaners) or replacement (media air
cleaners).
The Service Indicator automatically calculates the service
interval based on the pollution level selected and the fan speed.
If the filter becomes clogged the led • and •••• will flash each
time the air cleaner is turned on.
Pollution level guidelines for establishing setting:
• LOW DUTY: general pollution without tobacco smoke
•• MEDIUM DUTY: moderate tobacco smoke concentrations
••• HEAVY DUTY: high tobacco smoke concentrations
•••• EXTREME DUTY: extremely high tobacco smoke
concentrations
To select the pollution level:
Press
; you are in the program mode 1 and
PROGRAM
led will flash once every two seconds.
Default:
(all leds off).
OFF
Press
: led • (
) will light up, meaning you've set the
LOW
pollution level to LOW DUTY.
Press
: led •• (
MEDIUM
the pollution level to MEDIUM DUTY.
Press
: led ••• (
) will light up, meaning you have set
HIGH
the pollution level to HEAVY DUTY.
Press
: led •••• (
TURBO
the pollution level to EXTREME DUTY.
If you want to go back to one of the previous pollution
levels, press
.
Press
to confirm setting 1 and to go to setting 2.
PROGRAM
0508082120/101203/C
) will light up, meaning you have set
) will light up, meaning you have set
Program Setting 2: Resetting the Service Indicator
The indicator needs to be reset when the media filter is changed
out. If led • and led •••• are flashing, it is time to change the
filter(s) and to reset the indicator.
To Reset:
Press
PROGRAM
led will flash twice every two seconds.
STANDBY
Default:
OFF
If the indicator is programmed (setting 1), you will see all the
leds switched on in setting 2, provided the Service Indicator
is in use for a while.
Reset Service Indicator: press
Press
PROGRAM
cleaner is back in normal control.
Program Setting 3: Maximum fan speed for Air Quality
Analyzer (
AUTO
It is not possible to go directly to setting 3.
If the panel button (> > ) and then the
simultaneously before confirming setting 2, you're in setting 3
and
led will flash three times every two seconds.
STANDBY
Adjusting the maximum fan speed for the Air Quality Analyzer
is very convenient for meeting rooms and open plan offices.
Default: •••• (
Press
and so on to go to the desired maximum fan speed.
Press
PROGRAM
Program Setting 4: Manual lock
In setting 4
STANDBY
STANDBY
Blocking the panel button (> > ), to ensure that non-authorised
people cannot control the air cleaner.
Default: unlock; no leds are burning.
Press
or
Press
or
Press
PROGRAM
Program Setting 5: Voltage output for maximum
efficiency (Electronic Air Cleaners only)
In setting 5
STANDBY
This setting can be used to lower the efficiency (up to 10% at
low HV). This will increase the time between cleaning intervals.
Default: high HV level (7600 V); leds •, •• and ••• are
burning.
Page 7
: you are in the program mode 2 and the
(all leds are off).
(all leds are off).
OFF
: all user settings are saved and the air
mode)
PROGRAM
).
TURBO
: confirm setting 3 and go to setting 4.
led will flash four times every two seconds.
: lock; led • (
) is burning.
LOW
: unlock; led • (
) is off.
LOW
: confirm setting 4 and go to setting 5.
led will flash five times every two seconds.
key are pressed