Installation

How to Install the Unit
• There are sharp edges that can cause serious cuts.
• If the unit is to be installed close to the seaside, it needs
additional treatment on the heat exchanger.
• When lifting the air conditioner, it is HEAVY.
Use 2 people to lift.
For existing sleeve, you should measure the wall sleeve
dimensions.
You can install the new air conditioner according to these
installation instructions to achieve the best performence. All
wall sleeves used to mount the new air conditioner must be in
good structural condition and have the rear grille that securely
attaches to the sleeve or the flange of the sleeve to secure the
new air conditioner.
• To avoid vibration and noise, make sure the unit is installed
securely and firmly.
When installing the sleeve & Front grille, make certain there is
nothing within 20" back & front of sleeve & front grille, that
would interfere with heat radiation and exhaust air flow.
• Before installation, Check the insulation on the inner side of
the sleeve. If there is no insulation, place the insulation.
• Check the bottom corner's joint gap of the sleeve, If there is,
fill the gap with putty.
To maintain the best performance
NOTICE
of LG PTAC
1. An insulation strip must be attached. The
insulation strip is provided with the box.
2. After assembly of sleeve & Front grille, the
gap should be 20" from both sleeve &
grille. For assembly PTAC Model refer the
diagram given below.
1) Take out the insulation strip from the upper packing.
2) Attach the insulation strip onto the rear upper side of the
wall sleeve.
3) If anyone would like to improve unit energy efficiency, it is
recommended the change of outside grille for an unit
protection and an addition of a plastic rear grille. (This is
optional.)
Dimension of air conditioner
Dimension of sleeve assembly (optional)
Insulation
Joint Gap
INSULATION
COOLED
AIR
INTAKE
AIR
1/4" Bubble
of the level
Over 20"
280 mm
(11")
Sleeve
Rear
Installation
1,066 mm
(42")
406 mm
(16")
318 mm
(12
/
")
1
2
505 mm
(20")
1066 mm
(42")
406 mm
(16")
318 mm
(12
/
")
1
2
SLEEVE
WALL
HEAT
RADIATION
WALL
Over 20"
Insulation Strip
Front
Ownerʼs Manual 11