Sharp LC-60LE650U Service Manual page 79

Hide thumbs Also See for LC-60LE650U:
Table of Contents

Advertisement

LC-60/70/80LE650U/LE657U/C6500U/LE757U/LE857U,60/70LE755U/C7500U
Adjustment
Adjustment conditions
point
LEV30116
MG3G****
MG3B****
MG3R****
Point 2
LEV20074
MG2G****
MG2B****
MG2R****
Point 1
LEV10045
MG1G****
MG1B****
MG1R****
Writing
MSET0003
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
Level
Reference value
X=0.272
Point 6
916
y=0.277
X=0.272
Point 5
692
y=0.277
X=0.272
Point 4
532
y=0.277
X=0.272
Point 3
464
y=0.277
X=0.272
Point 2
296
y=0.277
X=0.272
Point 1
180
y=0.277
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-80LE757U:Min 280cd/m2
LC-80LE857U:Min 369.6cd/m2
5 – 16
Adjustment procedure
Adjustment spec
±0.0010
±0.0010
±0.0015
±0.0020
±0.0030
±0.004
Inspection spec
±0.0020
±0.0020
±0.0030
±0.0040
±0.0060
±0.0080

Advertisement