Timing TSC 4037A Operation And Maintenance Manual

1 x 16 l1/l2 distribution amplifier

Advertisement

Quick Links

TSC 4037A
1 x 16 L1/L2 Distribution
Amplifier
Operations and Maintenance
Manual
4775 Walnut Street
Suite 1B
Boulder, CO 80301
USA
www.timing.com
Phone: (303) 939-8481
4037A Operations and Maintenance Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for Timing TSC 4037A

  • Page 1 TSC 4037A 1 x 16 L1/L2 Distribution Amplifier Operations and Maintenance Manual 4775 Walnut Street Suite 1B Boulder, CO 80301 www.timing.com Phone: (303) 939-8481 4037A Operations and Maintenance Manual...
  • Page 2 TSC 4037A 1 x 16 L1/L2 Distribution Amplifier Operations and Maintenance Manual Copyright © 2004-2006 Timing Solutions Corporation Timing Solutions is a trademark of the Timing Solutions Corporation. Other product and company names may be trademarks of their respective owners.
  • Page 3: Table Of Contents

    1: Introduction ....................... 4 1.1 Symbols............................... 4 1.2 About This Manual ..........................5 1.2.1 Conventions ..........................5 1.3 4037A Overview ..........................6 2: Installing and Setting Up the 4037A ................ 7 2.1 Safety First!............................7 2.2 Unpacking ............................7 2.3 Cleaning .............................. 8 2.4 Installing the 4037A..........................
  • Page 4: 1: Introduction

    1: Introduction Note FIRST READ THIS MANUAL THROUGHLY! This is especially true for the sections regarding Safety and Installation. 1.1 Symbols These symbols appear throughout the manual as well as on the unit itself Note This symbol means the following information is a note that gives you important information that may affect how you use the 4037A.
  • Page 5: About This Manual

    “Chapter 3, Troubleshooting the 4037A” describes how to replace fuses and verify operational problems. “Chapter 4, Warranty and Shipping Information” explains how to contact Timing Solutions Corporation for warranty service and provides shipping guidelines. “Appendix A, Specifications” contains the detailed specifications for the 4037A.
  • Page 6: 4037A Overview

    1.3 4037A Overview The TSC 4037A is a one input, sixteen output L1/L2 amplifier housed in a 1U (1.75”) high 19 inch rack mount chassis. It provides sixteen outputs from a single input. The front panel provides green LED status for the voltage being supplied to the antenna (5V or 12V).
  • Page 7: 2: Installing And Setting Up The 4037A

    1. Unpack and carefully inspect the unit. 2. Check for physical damage. 3. If no physical damage is apparent, then proceed with making appropriate connections. If physical damage is observed, immediately contact Timing Solutions and the „ carrier. 4. Save the shipping container for submitting any necessary claims to the carrier.
  • Page 8: Cleaning

    2.3 Cleaning Warning Do not spray or use too much liquid when cleaning the unit. Liquid can enter the unit and damage sensitive electronic components. Clean the main chassis with a soft cloth dampened with a mild soap and water solution. 2.4 Installing the 4037A The 4037A is shipped ready for installation into a standard 19"...
  • Page 9: Input Signal And Antenna Bias Setting

    2.4.2.2 Output Signals Connect up to sixteen cables to the OUTPUT TNC connectors on the rear panel of the unit to supply users with a copy of the input signal. 2.4.3 Input Signal and antenna bias setting Before connecting the antenna input signal, ensure that the antenna bias supply voltage jumper is set to the position which will provide the proper voltage to your antenna.
  • Page 10: 3: Troubleshooting The 4037A

    Perform all of the following procedures before returning the unit for service. If the unit still appears to have a problem, then call Timing Solutions Corporation and request technical support. Have the serial number of your unit ready to provide to a technical representative.
  • Page 11: 4: Warranty And Shipping Information

    This chapter provides information on how to contact Timing Solutions Corporation for warranty service, as well as shipping guidelines for the 4037A. 4.1 Warranty Information The 4037A carries a warranty from Timing Solutions Corporation for a period of 1 year from date of shipment. For repairs, contact Timing Solutions Corporation: Phone (303) 939-8481 „...
  • Page 12: 5: Declaration Of Conformity

    5: Declaration of Conformity Timing Solutions Corporation 4775 Walnut Drive Suite 1B Boulder, CO 80301 declare that: Equipment 1 x 16 L1/L2 Distribution Amplifier Model Number TSC 4037A Product Options None in accordance with the following Directives: 73/23/EEC The Low Voltage Directive...
  • Page 13: Appendix A: Specifications

    Appendix A: Specifications A.1 Electrical Specifications Table 3: Table 3 lists the electrical specifications for the 4037A. Table 3: Electrical specifications Item Specification Protection Class Class I (Grounded Type) Power Input Voltage 100 – 240 V~ 50/60 Hz 0.5 A Note: Fluctuations not to exceed ±...
  • Page 14 A.2 Environment Specifications Warning Ordinary protection: This unit is for INDOOR USE ONLY. It is not protected against a harmful ingress of moisture. Equipment intended to be installed in an Enclosed/Open type equipment rack. Pollution Degree 2 per EN61010-1 „ Installation (Over-Voltage) Category II for transient over-voltages per EN 61010-1 „...
  • Page 15: Glossary

    Glossary electrostatic discharge light-emitting diode portable document format printed wiring assembly radio frequency Timing Solutions Corporation 4037A Operations and Maintenance Manual...
  • Page 16: Index

    Index Numerics 4037A operational problems cleaning 8 verifying 10 front panel 6 installing 8 output overview 6 connectors 9 rear panel 6 output signal connecting 9 required cables 8 specifications 13 unpacking 7 packing instructions 11 panels Antenna bias setting 9 front 6 rear 6 power...

Table of Contents