Frigidaire GLEQ942CS0 Installation Instructions Manual

Gas & electric dryer
Hide thumbs Also See for GLEQ942CS0:

Advertisement

Frigidaire
Installation
Instructions
Gas &
Electric
Dryer
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure
the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.
NOTE: The gas service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Fuel Gas Code ANSI Z223.1.
NOTE: The Dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 (latest editions) for HOME
USE only. This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
www.frigidaire.com
Pre-Installation Requirements................................ 2
Electrical Requirements........................................ 2
Exhaust System Requirements............................ 3-4
Gas Supply Requirements..................................... 4
Location of Your Dryer..........................................4-5
Mobile Home Installation....................................... 6
Rough-In Dimensions.......................................... 6-7
Unpacking........................................................... 7
Reversing Door Swing........................................... 7
Electrical Installation............................................. 8
Grounding Requirements....................................... 8
Electrical Connections-4-wire.............................. 9
Gas Connection................................................... 10
General Installation.............................................. 10
Replacement Parts.............................................. 10

Save These Instructions

1
P/N 134306200 (0310)

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire GLEQ942CS0

  • Page 1: Table Of Contents

    Leave these instructions near the Dryer after installation for future reference. NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70.
  • Page 2: Pre-Installation Requirements

    POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz, Alternating Current. POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord. NOTE: Do not under...
  • Page 3: Exhaust System Requirements

    Explosion hazard. Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.
  • Page 4: Gas Supply Requirements

    However, on electric dryers, exhausting can be to the right or left side of the cabinet or the bottom of the dryer. On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer. Directional exhausting can be accomplished by installing Exhaust Kit, P/N 131456800, available through your parts distributor.
  • Page 5 NOTE: Under counter and stack models - 0 inches (0 cm) for sides, rear, and top. This dryer MUST be exhausted outdoors. 5. The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation.
  • Page 6: Mobile Home Installation

    Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2. If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure.
  • Page 7: Unpacking

    (68.6 cm) SIDE VIEW 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping base. as a means to pick up or move the dryer. NOTE: On under counter model clothes dryers, the top 2.
  • Page 8: Electrical Installation

    A U.L. approved strain relief must be installed onto power cord. If the strain relief is not attached, the cord can be pulled out of the dryer and can be cut by any movement of the cord, resulting in electrical shock.
  • Page 9: Electrical Connections

    5. Attach the green power cord ground wire to the cabinet with the green ground screw. 6. Attach the white (neutral) power cord conductor from the power cord and the green ground wire from the dryer harness to the silver-colored center terminal on the terminal block. Tighten the screw securely.
  • Page 10: Gas Connection

    1. Connect the exhaust duct to outside exhaust system (see pages 3 and 4). Use duct tape to seal all joints. 2. With the dryer in its final position, adjust one or more of the legs until the dryer is resting solid on all four legs.

This manual is also suitable for:

Glgq942cs0Electric dryerGas dryer